Application of the multichannel electrode method to monitoring of corrosion of steel in an artificial crevice
スポンサーリンク
概要
- 論文の詳細を見る
Crevice corrosion of iron was evaluated using the multichannel electrode method in which ten individual working electrodes (WEs) of pure iron were embedded in resin, placed in an artificial crevice in the range from 0.5 mm to 2.0 mm, and immersed in 0.51 mol dm^[-3] NaCl solution. The WEs were connected to an electronic circuit which allowed galvanic coupling between them and measurement of their individual coupling current or open circuit potential. Time-transient of the spatial distribution of coupling current and open circuit potential showed sequential transition of the coupling current on WEs at the middle position of the crevice from cathode to anode. The WE near the opening of the crevice initially showed a large anodic current, then a decreasing the anodic current corresponding to the current transition of other WEs, and finally a large cathodic current coupled with the other anodic WEs in the crevice. The transition of coupling current was explained by the change in pH and concentration of dissolved oxygen in the crevice. Thickness of the gap of the artificial crevice affected the transition behavior of coupling current distribution. For example, slower current transition with smaller coupling current was found in the case of a narrower gap. Such properties were related to the introduction and consumption of dissolved oxygen in the crevice solution and the circulation of gap solution from/to the outside of the crevice.
論文 | ランダム
- Percutaneous Ethanol Injection under Interventional Radiographic Computed Tomography-Fluoroscopic Guidance for the Treatment of Small Hepatocellular Carcinomas
- 鉄塩誘導てんかんモデルラット脳におけるDNA損傷について(神経伝達物質・生化学)
- グアニジノ化合物によるラット脳内ヒドロキシルラジカルの生成(生化学・代謝・他)
- Electron apin resonance-computed tomographyによるラット鉄塩誘導てんかん焦点組織の画像について(生化学・実験てんかん)
- 抗てんかん薬のフリーラジカル消去作用について(薬理)