Influence of heat input waveform on transient critical heat flux of subcooled water flow boiling in a short vertical tube
スポンサーリンク
概要
- 論文の詳細を見る
The transient critical heat fluxes (CHFs) of the subcooled water flow boiling for ramp-wise heat input [Q = αt, α = 6.21 × 108 to 1.63 × 1012 W/m3 s, (q 1.08 × 107 to 6.00 × 107 W/m2)] and stepwise one [Q = Qs, Qs = 0 W/m3 at t = 0 s and Qs = 2.95 × 1010 to 7.67 × 1010 W/m3 at t > 0 s, (q = 0 W/m2 at t = 0 s and q 1.61 × 107 to 3.87 × 107 W/m2 at t > 0 s)] with the flow velocities (u = 4.0–13.3 m/s), the inlet subcoolings (ΔTsub,in = 86.8–153.3 K) and the inlet pressures (Pin = 742.2–1293.4 kPa) are systematically measured by an experimental water loop comprised of a pressurizer. The SUS304 tubes of inner diameters (d = 3, 6 and 9 mm), heated lengths (L = 33.15, 59.5 and 49.3 mm), L/d (=11.05, 9.92 and 5.48), and wall thickness (δ = 0.5, 0.5 and 0.3 mm) respectively with the rough finished inner surface (surface roughness, Ra = 3.18 μm) are used in this work. The experimental errors in the subcooling measure and the pressure one are ±1 K and ±1 kPa, while in the heat flux it is ±2%. The transient CHF data for the ramp-wise heat input and the stepwise one are compared with those for the exponentially increasing heat input (Q = Q0 exp(t/τ), τ = 16.82 ms to 15.52 s) previously obtained and the dominant variables on transient CHF for heat input waveform difference are confirmed. The transient CHF data are compared with the values calculated by the steady state CHF correlations against inlet and outlet subcoolings, and the applicability of steady state CHF correlations is confirmed extending its possible validity for the reduced time, ωp, down to 800 ms. The transient CHF data are compared with the values calculated by the transient CHF correlations against inlet and outlet subcoolings, and the influence of heat input waveform on transient CHF is clarified based on the experimental data for the ramp-wise heat input, the stepwise one and the exponentially increasing one. The dominant mechanisms of the subcooled flow boiling critical heat flux for the ramp-wise heat input, the stepwise one and the exponentially increasing one are discussed.
論文 | ランダム
- 高校と大学の教育の連続性について
- 10C-5 少ない内容で,多くを学ぶ算数の指導 : 2年 図形領域の学習を通して(第10分科会 学習指導法 第11分科会 ティーム・ティーチング,I 幼稚園・小学校部会,日本数学教育学会第83回総会全国算数・数学教育研究(埼玉)大会)
- 10B-8 立体図形についての理解を深める指導の一考察 : 第6学年「立体」の指導を通して
- タンパク質の水和と溶質の結合 : 選択的相互作用(Preferential Interaction)との関係
- 「こらーる岡山」の活動内容 (第36回日本臨床心理学会総会記録号) -- (分科会1 これでえーんか!精神保健福祉--精神保健福祉の現状と課題〔含 討論〕)