Specific Absorption Rates of Anatomically Realistic Human Models Exposed to RF Electromagnetic Fields From Mobile Phones Used in Elevators
スポンサーリンク
概要
- 論文の詳細を見る
This paper presents a detailed numerical investigation to determine whether or not an increased specific absorption rate (SAR) in an adult using a mobile phone inside an elevator due to the multireflections of electromagnetic fields from the walls exceed the RF-exposure guidelines. A fully realistic heterogeneous human body model and an actual elevator size were employed. The nonuniform mesh finite-difference time-domain technique and a supercomputer were employed to obtain the SAR and other important parameters. The mobile phone was modeled as a λ/2 dipole antenna placed at a distance of 16 mm from the head. For computations, operating frequencies of 900, 1500, and 2000 MHz with transmitting power of 250 mW were used. Computed results show that the peak spatial-average 10-g SAR depends on the position of the passenger and the antenna against the elevator walls. We observed a substantial increase in the whole-body average SAR and peak 10-g SAR values of the passenger in the elevator over their respective free-space values. However, the maximum values obtained do meet the basic restrictions described in the international RF safety guidelines. For example, the maximum values of the whole-body average and peak spatial-average SAR were 4.4% and 78% of the international RF safety guideline, respectively.
- IEEEの論文
著者
-
Watanabe Soichi
NICT
-
Hikage Takashi
Hokkaido Univ. Sapporo‐shi Jpn
-
Hikage Takashi
Hokkaido University
関連論文
- Precise Measurement of IMD Behavior in 5-GHz HTS Resonators and Evaluation of Nonlinear Microwave Characteristics
- B-4-38 Thresholds Inducing Behavioral Sign of Thermal Stress for 2.45-GHz Microwave Exposure in Rabbits
- The Measurements of the Complex Permittivities of Blood Samples in Quasi-Millimeter and Millimeter Wave Bands(2nd Pan-Pacific EMC Joint Meeting-PPEMC'06-)
- Using Large-Scale FDTD Method to Obtain Precise Numerical Estimation of Indoor Wireless Local Area Network Office Environment
- Precise Estimation of Cellular Radio Electromagnetic Field in Elevators and EMI Impact on Implantable Cardiac Pacemakers
- A Novel Filter Construction Utilizing HTS Reaction-Type Filter to Improve Adjacent Channel Leakage Power Ratio of Mobile Communication Systems
- Microwave superconducting reaction-type transmitting filter using split open-ring resonator
- FDTD simulation of temperature elevation in rabbit eye due to microwave energy (環境電磁工学)
- Temperature Elevation in the Eye of Japanese Male and Female Models for Plane Wave Exposures
- Temperature Elevation in Rabbit Eye Irradiated by 2.45-GHz Exposure Systems
- Development of Computational Model for Rabbit Eye and Its Application to Temperature Calculation for Near-Field Microwave Exposures
- Simultaneous Measurement of Antenna Gain and Complex Permittivity of Liquid in Near-Field Region Using Weighted Regression
- A Method of Measuring Gain in Liquids Based on the Friis Transmission Formula in the Near-Field Region(Measurements,2006 International Symposium on Antennas and Propagation)
- Specific Absorption Rates of Anatomically Realistic Human Models Exposed to RF Electromagnetic Fields From Mobile Phones Used in Elevators
- B-4-3 Numerical Investigation of Passive RF-Exposure Due to Mobile Phone Usage in an Elevator.
- B-4-21 MOBILE-PHONE RF EXPOSUSE FOR MULTIPLE USERS SITUATION IN SEMI-ECHOIC ENVIROMENT : A NUMERICAL INVESTIGATION OF SAR AT 900, 1500 AND 2000MHz
- B-4-24 SAR Calculation of a Realistic Human Model Due to RF Exposure From Mobile Phones in Elevators at 900, 1500 and 2000 MHz
- Electric-Field Distribution Estimation in a Train Carriage due to Cellular Radios in order to Assess the Implantable Cardiac Pacemaker EMI in Semi-Echoic Environments(Biological Effects, 2004 International Symposium on Electromagnetic Com
- Formula for estimating whole-body average SAR in human models due to plane-wave exposure at resonance frequency (環境電磁工学)
- B-4-25 Uncertainty of Temperature Elevation in the Eye Due to Microwave Energy
- Effect of Heterogeneity of Tissues on RF Energy Absorption in the Brain for Exposure Assessment in Epidemiological Studies on Mobile Phone Use and Brain Tumors
- Electromagnetic and Thermal Dosimetry of a Cylindrical Waveguide-Type in vitro Exposure Apparatus(Biological Effects, 2004 International Symposium on Electromagnetic Compatibility)
- Human Body Impedance for Contact Current Measurement in Japan(Biological Effects, 2004 International Symposium on Electromagnetic Compatibility)
- Estimation of EMI Impact by Cellular Radio on Implantable Cardiac Pacemakers in Elevator Using EMF Distributions Inside Human Body
- Experimental Quasi-Microwave Whole-Body Averaged SAR Estimation Method Using Cylindrical-External Field Scanning
- Basic Construction of Whole-Body Averaged SAR Estimation System Using Cylindrical-External Field Scanning for UHF Plane Wave Irradiation of Human Models
- In vitro Assessment of Electromagnetic Interference due to Low-Band RFID reader/writers on Active Implantable Medical Devices
- SAR-Probe Calibration System Using Reference Dipole Antenna in Tissue-Equivalent Liquid