The train shunting resistance has been measured, but it has been mainly performed on the condition that the truck circuit was closed. This method has a problem that an accurate value cannot be measured at some position of the train. This time, open truck circuit is constructed so that fluctuation is decreased. And we performed long-term measurement that the variation of the leakage current is considered. Additionally, the voltage between normal rails and the train shunt resistance in the case of that short-circuit current is changed. In this paper, we describe the report and the consideration of the the train shunt resistance measured under the most suitable environment in the train.