B215 NUMERICAL SIMULATIONS OF COMBUSTION OPTIMIZAITON FOR A 600 MW TENGENTIALLY COAL-FIRED SUPER-CRITICAL BOILER(Combustion-8)
スポンサーリンク
概要
- 論文の詳細を見る
Numerical simulations of combustion optimization under multi-operating modes have been performed for a 600 MW tangentially coal-fired super-critical boiler. Under rated boiler load, the computational combustion efficiency of pulverized coal of 99.5% and nitrogen oxides (NOx) emission less than 400 mg/Nm^3 (6% O_2) agree well with the experimental data. For the high combustion efficiency of pulverized coal and low NOx emission, some combustion optimization information should be conducted as follows: (1) A double V-shaped (DV) secondary air distribution mode and more under fire air (UFA) are recommended. (2) The air flow of separated over fire air (SOFA) is not less than 75% of designed value. (3) The tilting angle of SOFA burner in horizontal direction is bigger than zero degree. (4) Under the load of 450MW, the lowest four primary air burner nozzle layers are recommended to be in service. (5) Under the load of 300MW, the intermediate three primary air burner nozzle layers are recommended to be in operation.
- 2009-11-16
著者
-
ZHANG Cheng
State Key Laboratory of Networking and Switching Technology, Beijing University of Posts and Telecom
-
FANG Qing-yan
State Key Laboratory of Coal Combustion, Huazhong University of Science and Technology
-
Fang Qing-yan
State Key Laboratory Of Coal Combustion Huazhong University Of Science And Technology
-
CHEN Gang
State Key Laboratory of Coal Combustion, Huazhong University of Science and Technology
-
XU Yuan-Gang
State Key Laboratory of Coal Combustion, Huazhong University of Science and Technology
-
Chen Gang
State Key Laboratory Of Coal Combustion Huazhong University Of Science And Technology
-
Zhang Cheng
State Key Laboratory Of Coal Combustion Huazhong University Of Science And Technology
-
Xu Yuan-gang
State Key Laboratory Of Coal Combustion Huazhong University Of Science And Technology
-
Zhang Cheng
State Key Laboratories For Agrobiotechnology And Department Of Animal Physiology And Biochemistry Co
-
CHEN Gang
State Key Laboratory for Strength and Vibration of Mechanical Structures, School of Aerospace, Xi'an Jiaotong University
関連論文
- Reducing the Inaccuracy Caused by Inappropriate Time Window in Probabilistic Fault Localization
- B215 NUMERICAL SIMULATIONS OF COMBUSTION OPTIMIZAITON FOR A 600 MW TENGENTIALLY COAL-FIRED SUPER-CRITICAL BOILER(Combustion-8)
- B302 EXPERIMENTAL STUDY OF OPTIMIZAITON CONTROL FOR A LARGE-SCALE COAL-FIRED UTILITY UNIT USING RADIATIVE ENERGY SIGNAL(Combustion-9)
- B217 VISUALIZATION DETECTIONS OF THE COMBUSTION IN A 300-MW ARCH-FIRED BOILER(Combustion-8)
- D207 A STUDY ON THE FEASIBILITY OF CO-COMBUSTION OF SEWAGE SLUDGE AND COAL IN THE COAL-FIRED POWER PLANT(Biomass-5)
- Silencing of Mouse Hepatic Lanosterol 14-α Demethylase Down-Regulated Plasma Low-Density Lipoprotein Cholesterol Levels by Short-Term Treatment of siRNA(Pharmacognosy)
- Reducing the Inaccuracy Caused by Inappropriate Time Window in Probabilistic Fault Localization
- High Sensitivity Measurement and Accurate Analysis of the Vibrational Spectroscopy Near the (6\text{S}_{1/2}+6\text{P}_{3/2}) Dissociation limit for 1g State of Cs2
- Active Aeroelastic Control using Multiple Control Surfaces Based on a High-Fidelity Reduced Order Model
- Limit Cycle Oscillation Control for Transonic Aeroelastic Systems Based on Support Vector Machine Reduced Order Model