2205 発光分光法による予混合火炎の挙動の計測(G06-4 熱工学(4) 燃焼(2),21世紀地球環境革命の機械工学:人・マイクロナノ・エネルギー・環境)
スポンサーリンク
概要
- 論文の詳細を見る
It has been thought that the local extinction of turbulent premixed flames occurs due to the local flame stretch. However, the local extinction of turbulent premixed flames has never been observed experimentally because the definitive experimental technique to detect the local extinction has not been established. The objective of the present study is to establish the definitive experimental technique to detect the local extinction of turbulent premixed flames by measuring emissions of intermediate species from hydrocarbon-air premixed flames. Emission intensities of OH, CH. and C_2. the major intermediate species of the hydrocarbon-air flame have been examined. It has been shown that the unique relation exists between flame temperature and the ratio of the emission intensities of the C_2 470 nm and 515 nm bands. implying that the flame temperature can be estimated by measuring the ratio of the emission intensities of the C_2 470 nm and 515 nm bands.
- 一般社団法人日本機械学会の論文
- 2008-08-02
著者
関連論文
- 2205 発光分光法による予混合火炎の挙動の計測(G06-4 熱工学(4) 燃焼(2),21世紀地球環境革命の機械工学:人・マイクロナノ・エネルギー・環境)
- 136 乱流予混合火炎における火炎と流れの相互作用
- 218 乱流予混合火炎における火炎と流れの相互作用