Quantitative Evaluation of Luminance Nonuniformity "Mura" in LCDs Based on Just Noticeable Difference (JND) Contrast at Various Background Luminances(<Special Section>Electronic Displays)
スポンサーリンク
概要
- 論文の詳細を見る
An analytical approach using human perception has been applied to the evaluation of the front-of-screen (FOS) quality of liquid crystal displays (LCDs), particularly regarding the regions of luminance nonuniformity called "muras." The accurate and consistent inspection of muras is extremely difficult because muras have various shapes and sizes as well as contrasts. And inspection results tend to depend on inspectors during the LCD manufacturing process. To determine the quantitative scale that shows the evaluation results of mura matching human perceptions, first, we conducted a perception test and clarified the "just noticeable difference" (JND) contrast according to the type of mura. Second, the relationship between the JND contrast of mura and background luminance was investigated. Finally, we proposed a quantitative scale of mura level on the basis of the JND contrasts at various background luminances. In this paper, we describe our research on human perception of muras at various background luminances and an approach to determining the quantitative scale of visible muras.
- 社団法人電子情報通信学会の論文
- 2006-10-01
著者
-
Satoh Toshifumi
Department Of Media And Image Technology Tokyo Polytechnic University
-
UCHIDA TAKAYUKI
Department of Cardiovascular Surgery, Faculty of Medicine, Kyushu University
-
Uchida Takayuki
Tokyo Polytechnic Univ. Atsugi‐shi Jpn
-
TAMURA Tohru
Department of Media and Image Technology, Tokyo Polytechnic University
-
FURUHATA Takashi
Department of Media and Image Technology, Tokyo Polytechnic University
-
Satoh Toshifumi
Department Of Image Engineering Tokyo Polytechnic University
-
Tamura Tohru
Department Of Media And Image Technology Tokyo Polytechnic University
-
Furuhata Takashi
Department Of Media And Image Technology Tokyo Polytechnic University
-
Uchida Takayuki
Department Of Cardiovascular Surgery Kyushu University
-
Uchida Takayuki
Department Of Cardiovascular Surgery Faculty Of Medicine Kyushu University
関連論文
- Human Skin Xenograft Rejection in CD45 Exon-6 Knockout Mice : The Implication of Involvement of a Direct Pathway
- Quantitative Evaluation of Luminance Nonuniformity "Mura" in LCDs Based on Just Noticeable Difference (JND) Contrast at Various Background Luminances(Electronic Displays)
- Hot-Carrier Degradation in Low-Temperature Polycrystalline Silicon n-Channel Lightly Doped Drain Thin-Film Transistors
- Mechanization of Refractory Repair Work with Centrifugal Force Shot Method (Rotary-Shot Method)
- Cerebellar Malignant Glioma after Radiation Therapy for Suprasellar Germinoma : Case Report
- -0947- EFFECTS OF LAZAROID(U-74500A)ON LIPID PEROXIDATION AND CARDIAC FUNCTION AFTER REPERFUSION IN BLOOD PERFUSED RABBIT HEARTS(PROCEEDINGS OF THE 59th ANNUAL SCIENTIFIC MEETING OF THE JAPANESE CIRCULATION SOCIETY)
- Two-Dimensional Simulation of Electric Field and Carrier Concentration of Low-Temperature N-Channel Poly-Si LDD TFTs(Junction Formation and TFT Reliability,Fundamentals and Applications of Advanced Semiconductor Devices)
- Hot-Carrier-Induced Degradation under Current Saturation Bias in p-Channel Low-Temperature Polycrystalline Silicon Thin-Film Transistors
- Hot-Carrier Degradation and Electric Field and Electron Concentration near Drain Junction in Low-Temperature N-Channel Single Drain and Lightly Doped Drain Polycrystalline Silicon Thin Film Transistors
- Glare-Tunable Transparent Electrochemical Smart Window Coupled with Transparent Organic Light-Emitting Diode
- Smart Windows, Switchable between Transparent, Mirror, and Black States, Fabricated Using Rough and Smooth Indium Tin Oxide Films Deposited by Spray Chemical Vapor Deposition
- Endovascular Surgery for Traumatic Thoracic Aortic Injury: Our Experience with Five Cases, Two of Whom were Young Patients