Assessment of wind ventilation performance inside a street located within a dense urban area using exceedance probability (特集 乱流シミュレーションと流れの設計(TSFD))
スポンサーリンク
概要
- 論文の詳細を見る
The present study aims to estimate the wind ventilation performance for pedestrian level domains from the air quality point of view. Four typical models of a densely built-up area were considered and numerically simulated in order to examine the effects of the geometry of such models on wind flow characteristics, which in turn affect the air quality, within the pedestrian domain of a street located within this area. The calculated flow fields were employed to estimate the exceedance probabilities within the study domain using air exchange rate within the domain. The air exchange rate represents air quality. The study has been applied to nine cities in Japan: Tokyo, Osaka, Sapporo, Niigata, Fukuoka, Nagoya, Sendai, Yokohama, and Kyoto, based on their mean wind velocity data. The results demonstrated that the exceedance probability analysis of the pedestrian wind environment is very important during the design stage of inhabited areas for the evaluation of pollutant-removal efficiency by the applied wind. Also, the calculated probabilities demonstrated substantial dependence on both the geometry of building arrays and the wind conditions of the nine cities. [This abstract is not included in the PDF]
- 東京大学の論文
著者
-
加藤 信介
Institute of Industrial Science, University of Tokyo
-
Ishida Yoshihiro
Institute Of Industrial Science The University Of Tokyo
-
Bady Mahmoud
Graduate School of Engineering, The University of Tokyo
-
Kato Shinsuke
Institute of Industrial Science, The University of Tokyo
-
Huang Hong
Institute of Industrial Science, The University of Tokyo
-
Takahashi Takeo
Institute of Industrial Science, The University of Tokyo
-
Huang Hong
Institute Of Industrial Science The University Of Tokyo
-
Kato Shinsuke
The Univ. Of Tokyo Komaba Meguro-ku Tokyo Jpn
-
Kato Shinsuke
Institute Of Industrial Science The University Of Tokyo
-
Kato Shinsuke
Institute Of Industrial Science University Of Tokyo
-
Takahashi Takeo
Institute Of Industrial Science The University Of Tokyo
-
Takahashi Takeo
Institute For Cardiovascular Diseases Tokyo Ika-shika National University
-
石田 義洋
Institute of Industrial Science, The University of Tokyo
関連論文
- A Preliminary Study of a Method to Measure SVOCs Emitted from Electrical Appliances(Environmental Engineering)
- 41338 風向が都市ストリートキャニオン内のPFRに及ぼす影響に関するCFDおよび風洞実験(換気測定法・換気効率評価, 環境工学II)
- 41369 風力発電用風車建設最適地検討用の局所風況予測モデルに関する風洞模型実験(その3) : ステップ状地形周りの各種乱流統計量の測定(風力発電,環境工学II)
- 41408 その3 新鮮空気と排出空気の不同混合比例による室内化学物質の濃度分布の予測(化学物質の挙動解析,環境工学II)
- Assessment of wind ventilation performance inside a street located within a dense urban area using exceedance probability (特集 乱流シミュレーションと流れの設計(TSFD))
- Identification of pollution sources locations in outdoor environments using reverse simulation (part 1) Basics of reversed time marching method (特集 乱流シミュレーションと流れの設計(TSFD))
- 41417 屋根層の水分量蒸発に関する陸屋根の軒形状による屋根面風圧分布(風圧係数,環境工学II)
- Microbiochemical Studies on Changes of Phosphofructokinase and Glucose-6-Phosphate Dehydrogenase Activity in Intima and Media of Aortic Wall of Rabbits in the Course of Cholesterol Feeding
- An Electron Microscopic Studies of Membrane ATPase Activity in the Endothelial Cells of Rabbits Aorta
- Forecast of CO_2 Emissions from Construction and Operation of Buildings in Japan Up to 2050
- Evaluation of Wind Breeze Properties of City-Block-Scale Voids by Using Local Ventilation Efficiency Index
- S05-1 A Three-dimensional Human Thermal Model for Evaluation of Nonuniform Thermal Environments(Proceedings of The 8th International Congress of Physiological Anthropology)
- Glycogen in Endothelial Cells of Vessel Wall : Electron Microscopical Studies of Polyglucose Synthesized by Phosphorylase in Endothelial Cells of Aorta and Heart Muscles of Rabbits
- Analysis of Ventilation Efficiency Indices Inside a Local Domain in an Urban Area Using Two Building Model(Part1)Effect of Void Width and Building Height (特集 乱流シミュレーションと流れの設計(TSFD))
- Analysis of ventilation efficiency indices inside a local domain in an urban area using two building model (part 2) Effect of wind direction (特集 サスティナブルITS--先進モビリティ連携研究センター(ITSセンター))
- CFD Analysis on Traffic-Induced Air Pollutant Dispersion with Non Isothermal Condition in a Complex Urban Area in Winter
- Swinging Windowsを有する建物の換気性能に関する調査研究
- Study on Optimum Arrangement of Trees for Design of Pleasant Outdoor Environment Using Multi-Objective Genetic Algorithm And Coupled Simulation of Convection, Radiation and Conduction
- Analysis of ventilation efficiency indices inside a local domain within an urban area using two building model
- Analysis of Wind-Induced Inflow and Outflow through a Single Opening using Large-Eddy Simulations
- Wind-Induced Ventilation Analysis using Detached-Eddy Simulations to Control Indoor Thermal Environments
- CFD Analysis of Pollutant Distribution in a Room with Adsorptive Walls
- Numerical simulation of relationship between climatic factors and ground ozone concentration over Kanto area using the MM5/CMAQ model (特集 安全で快適な都市システムの実現をめざして(ICUS))
- Filtering for the Inverse Problem of Convection-Diffusion Equation with a Point Source
- Effects of Momentum and Climate in Physical Education Class on Students' Formative Evaluation
- B-17 非定常、不均一温熱環境における人体モデルに関する研究 : (第6報)不均一放射環境における顕熱伝達量分布
- Swinging Window を有する建物の換気性能に関する調査研究
- The Effects of Group Contingency Strategy on Students' Behaviors in Physical Education Classes in Korea Using Multiple Baseline Design
- O05-3 Evaluation of thermal sensation under the non-uniform thermal environment - Estimation of the equivalent temperature by the experiment
- H-69 市街地の風環境の研究 : (その5):密集市街地モデルにおける通風・換気性能に関する風洞実験
- Y1-4 Evaluation of thermal sensation under the non-uniform thermal environment : estimation of the equivalent temperature with thecomputational simulation