偏光ゼーマンバックグラウンド補正黒鉛炉原子吸光光度計による瀬田川水中のAl分析のためのマトリックス修正液の比較
スポンサーリンク
概要
- 論文の詳細を見る
Four different compositions, i. e., a mixture of magnesium and palladium nitrate,magnesium nitrate, palladium nitrate both dissolved in nitric acid, and magnesium nitratedissolved in pure water, were examined at high (1000ppm) and low (100ppm) concentrationsfor the suitability as the matrix modifier for the determination of aluminum in Seta Riverwater. For the determination, the standard addition method was employed and the slopesof the graph calculated by the peak-height mode and the peak-area mode were comparedto those of pure water. The chemical interference, evaluated as the ratio of these slopes,was smaller in the peak-area mode except for the 100ppm palladium. The matrix modifiersolutions containing palladium have a tendency to shorten the life of a pyrocoatedgraphite cuvette. The peak profile from the matrix modifiers containing nitric acid wasoften distorted at the initial rising part. We concluded that magnesium nitrate dissolvedin pure water (1000ppm) was the most appropriate matrix modifier for the determination ofaluminum in Seta River water from among the tested modifier solutions, although thechemical interference was not completely removed.
- 滋賀大学の論文
著者
-
原 博一
滋賀大学教育学部化学教室
-
Hara Hirokazu
Department Of Chemistry Faculty Of Education Shiga University
-
Hara Hirokazu
滋賀大学教育学部
関連論文
- 偏光ゼーマンバックグラウンド補正を備えた黒鉛炉原子吸光光度計による瀬田川水中のアルミニウム分析のための硝酸マグネシウムマトリックス修正液
- 琵琶湖における水質変動 : I.マンガン,鉄,栄養塩類の底泥からの再溶出と酸化還元サイクル
- 琵琶湖における水質変動 : I. マンガン、鉄、栄養塩類の底泥からの再溶出と酸化還元サイクル
- イオン選択性電極による硝酸イオン,亜硝酸イオン二成分系の同時定量
- p-t-オクチルフェノ-ルを液膜中に添加したアニオン界面活性材選択性電極(ノ-ト) (「センサ-と化学」) -- (イオン選択性電極--基礎と応用)
- 琵琶湖における水質変動 : II、南湖表層水におけるCOD, SS, リン, 窒素およびクロロフィルaの季節変化
- 琵琶湖における水質変動 : II.南湖表層水におけるCOD,SS,リン,窒素およびクロロフィルaの季節変化再溶出と酸化還元サイクル
- 瀬田川水中のアルミニウム有機錯体のルモガリオン蛍光検出陽イオンクロマトグラフ法による調査
- 偏光ゼーマンバックグラウンド補正黒鉛炉原子吸光光度計による瀬田川水中のAl分析のためのマトリックス修正液の比較
- 瀬田川水中の溶存アルミニウム濃度の一年間の変化
- ヘキサデシルトリメチルアンモニウムイオンを含むアルミニウム13量体硫酸塩の沈殿を用いた固体膜型硫酸イオン選択性電極
- フッ化イオン電極を検出器とする低濃度アルミニウムイオンの連続フロー分析システム
- イオン選択性電極を用いた硝酸イオン自動分析システムの開発
- High Speed Potentiometric Analyzer II Using a Suction-type Flow-cell and an Ion-selective Electrode Detector
- Continuous Flow Determination of Sulphate With Lead-selective Electrode
- アルミニウム-ルモガリオン錯体を用いるフローインジェクション蛍光光度定量における、サンプルループのアルミニウムの吸着
- Influence of signal operation mode on the determination of aluminum using the standard addition method by graphite furnace atomic absorption spectrometry
- Separation of Dissolved Aluminum in Neutral/Slightly Basic River Water by Cation-Exchange Chromatography with Fluorometric Detection of the Lumogallion-Aluminum Complex
- 瀬田川水中の溶存アルミニウム濃度の一年間の変化(2)
- Continuous-flow determination of nitrate in rain water using a nitrate ion-selective polymeric membrane electrode based on bis (bathocuproin)-copper (I) nitrate
- Effect of pioglitazone on various parameters of insulin resistance including lipoprotein subclass according to particle size by a gel-permeation high-performance liquid chromatography in newly diagnosed patients with type 2 diabetes
- Determination of Total Dissolved Aluminum in Seta River Water by Flow Injection Fluorometry with Aluminum-Lumogallion Complex after Acid Digestion
- Concentration Change of Dissolved Reactive Aluminum in Seta River Water During Storage : Comparison between the FIA Method and the Batch Method using Fluorometry with Aluminum-lumogallion Complex
- On the enhancement of the selectivity of organic sulfonate ion electrode by alkylphenols.
- An evaluation of ion-exchange membrane electrodes.
- 瀬田川水中の溶存反応性アルミニウムの保存中の濃度変化 : アルミニウム-ルモガリオン錯体を用いる蛍光光度法によるFIA法とバッチ法の比較
- 瀬田川水中の溶存アルミニウム濃度の一年間の変化(2)
- Preparation and analytical evaluation of liquid membrane electrodes based on solid-solvents.