819 熱源との熱交換を考慮した水スターリング熱機関の動作解析(G06-4 伝熱(2)・熱機関,G06 熱工学)
スポンサーリンク
概要
- 論文の詳細を見る
Two analytic models for a water-type Stirling engine were newly developed. One is the constant temperature model, assuming the constant temperatures of working fluid, and the other is the heat transfer model, considering with the heat transfer between the heat sources and the work fluid. The constant temperature model is a conventional model for analyses of a Stirling engine. However, in an actual Stirling engine the temperatures of working fluid are not perfectly fixed, and there is few literature on a water-type Stirling engine. Therefore, these analytic models were newly developed. Using these two analytic models, influences of the resonance pipe length and the heat transfer coefficient over the performance of the engine were investigated numerically, and the tendencies in optimum values of these parameters were shown.
- 一般社団法人日本機械学会の論文
- 2005-09-18
著者
関連論文
- 懇親会報告
- 4623 水スターリング熱機関の動作特性 : 共鳴管長さの影響(G06-5 熱・流動現象(1),G06 熱工学)
- 819 熱源との熱交換を考慮した水スターリング熱機関の動作解析(G06-4 伝熱(2)・熱機関,G06 熱工学)
- 1810 円管内における往復流動湿り空気による熱伝達の数値予測(G06-2 伝熱(2),G06 熱工学)