16 多層建築物における同時流出について
スポンサーリンク
概要
- 論文の詳細を見る
In case of the outbreak of a fire or other condition danderous to life in Multi-storey buildings, evacuations onto the stairs occur simultaneously from each floor soon after an alarm or the announcement to the occupants to leave the building. To minimize danger to life from fire, smoke, fumes or panic before building are vacated, there must be the means of exits sufficient to permit prompt escape of occupants. To obtain the adequacy of means of exits, it is first necessary to know the time which will be required for evacuation from each storey. Here, I tried for the method of calculating that time for evacuation as the base for determining necessary width of stairs, landings or platforms. But in order to ascertain the requisite width of staircase, it will first be necessary to assume a width and then to determine whether it is adequate. Number of storeys may range here 3 to 10, and the storey-heights, number of people and width of stair on each floor or storey may be varied or equal. The formulas are as follows. I. When the width of stairs are same throughout that vertical opening, and if evacuation from m-th floor other than top complete as final: [numerical formula] and if top floor is final: [numerical formula] II. When the width of stairs are different in lower and in upper storeys: [numerical formula], if top floor is final; [numerical formula] and if any of G_i (or T_i)<0, the required time for m-th floor to be clear is revised as [numerical formula] Here, [numerical formula] but G_1, G_2, G_3 take special types. Notations: N_m (person) Number of people on m-th floor. A_m(〃) Staircase capacity of m-th storey. U_m Width of stair of m-th storey in units (1 unit=55cm) V (person/minute/unit) discharge value (42 p/m/u) T_m, T_<nt>, G_m, G_<nt> Total time required for m-th floor to be clear. Suffix(t) means top. T is used when stair width equal, and G used when different. t_m' variable clause in T_m-formula. T_0 Required time before the announcement or alarm to all floors. G_m Time required from conclusion of discharge from m-1-th floor to that from m-th floor. g_m Variable clause in formula G_m C_n Variable clause. This varies according to the order of conclusions of discharge from floors.
- 社団法人日本建築学会の論文
- 1960-03-25
著者
関連論文
- 191 釣棚の寸法と曲尺割
- 48. 曲り階段に間する圖表 (II)
- 模型実験による流動特性 : その2. 小型鉄球の場合 : 建築計画
- 4-35 模型実験による流動特性(設計計画)
- 4-16 博覧会建築における避難計画要項(第4室 設計計画)
- 4039 博覧会建築に於ける避難計画の条件
- 3099 水平出口について(計画,昭和38年度(仙台)大会学術講演要旨集)
- 3091 百貨店における歩行距離(計画)
- 212 百貨店における階段の維持管理状況とその問題点(計画)
- 3081 多層建築物における同時流出について : 第8報・図式解法III(計画)
- 17) 多層建築物におるけ同時流出について : 第6報 個別的図式解法II
- 26. 百貨店における人員密度 : 多層建築物における同時流出, 第7報
- 3075 多層建築物における同時流出について : 第5報 個別的図式解法(計画)
- 14 多層建築物における同時流出について
- 16 多層建築物における同時流出について
- 47. 多層建築物における同時流出について 第2報 (その5)
- 46. 多層建築物における同時流出について 第2報 (その4)
- 45. 多層建築物における同時流出について 第2報 (その3)
- 43. 44. 多角建築物における同時流出について 第2報 (その1, その2)
- 3068 多層建築物における同時流出について(計画)
- 56. 歩行距離について(その2) : 諸法規の概観とその検討
- 55. 歩行距離について(その1) : 諸法規の概観とその検討
- 階段における単位巾について(2)
- 階段昇降における流出率(2)
- 階段昇降における流出率(1)
- 3052 単一階段に関する諸法規について(計画・設備)
- 319 階段に於ける単位幅についての考察(計画・設備)
- 階段に於ける群集流動の性状
- 73. 階段の容量
- 317 階段の容量 (II)
- 430. 階段の容量
- 42.螺旋階段図表について
- 190 奈良八窓庵細部実測報告
- 91. Stair Table試案
- 131. 曲り階段に関する図表
- 130. 階段算定図表 : 算定尺の図表化について
- 76 購買中心に於ける動線
- 斜透視図の写実性
- 斜透視における陰影について
- 斜透視における陰影について-2-仰観斜透視の場合
- 模型実験に基づく流動仮説