The estimation of oxy-and deoxy-hemoglobin (HbO_2 and Hb) concentration change in cerebral blood flow by near infrared spectroscopy (NIRS) has been being used for the assessment of cerebral function in recent years. However, some oscillating artifacts in the estimation seen even when subjects are in the resting state have made practical application difficult. This paper focuses on a method to eliminate the artifacts and level the baseline in the estimation. At first, we examined the appropriateness of the two-component model generally used in NIRS estimation, in which it is believed that HbO_2 and Hb alone cause the changes in absorbance. Several estimations based on observations at different wavelength couples were carried out. If the two-component model is appropriate, these estimations should be identical. However, they significantly differed from each other. In order to avoid this problem, we introduced a wavelength-independent component into the model. This component represents factors such as light scattering, transmittance change in optics, and absorbance change caused by other matter, which are not considered in the two-component model. The wavelength-independent artifact was eliminated by using the differences in absorbance at the point of wavelength coupling. The Wiener filter was used to stabilize the estimation. Compared with the two-component model, the proposed three-component model was able to level the baseline in the estimation of concentration change well. The power spectra of the concentration changes estimated by the two models were also compared. A peak at about 1.2Hz correlating with the heartbeat was observed in the case of the two-component model; however, it disappeared when the three-component model was used. This method is useful to eliminate artifacts in the estimation of concentration change in HbO_2 and Hb since it does not require any modification when used with multi-wavelength-type NIRS hardware.
- 社団法人日本生体医工学会の論文
- 2005-12-10
著者
-
山田 亨
産総研・脳神経情報
-
山田 亨
独立行政法人 産業技術総合研究所 脳神経情報研究部門
-
山田 亨
電子技術総合研究所
-
梅山 伸二
産業技術総合研究所脳神経情報研究部門
-
梅山 伸二
独立行政法人産業技術総合研究所脳神経情報研究部門
-
山田 亨
産業技術総合研究所 脳神経情報
関連論文
- 液晶偏光顕微鏡などを用いた数十nmオーダーの物体の検出
- アンジュレータ放射光の偏光変調を用いた真空紫外円二色性スペクトルの測定
- 円偏光真空紫外線および非偏光紫外線によるアミノ酸の化学進化に関する研究
- 7p-YL-14 紫外線によるアミノ酸の光分解量子効率と化学進化
- ガボールフィルタバンクと独立成分分析を用いた劣化過程未知のぼけ画像からの原画像復元
- 29a-L-10 シラン系ガスのアンジュレーター光による分解(原子・分子)
- 偏光可変アンジュレ-タを用いた円偏光顕微鏡の開発
- メリチンの脂質膜への結合とチャネルポア形成の反応過程
- 健常幼児にみられる浮き趾(うきゆび)の保育内容別発生状況
- 1P220 脳機能評価のための新たな脳血流動態モデルの提案(II) : 酸素輸送モデル(化学受容、神経・感覚、神経回路・脳の情報処理,口頭発表,第45回日本生物物理学会年会)
- 音が音楽になり,人間に与える影響 (特集 音楽療法と作業療法)
- 画像処理への独立成分分析の応用(独立成分分析とその応用特集号)
- 近赤外分光脳機能計測法における波長差分法を用いたベースライン安定化の試み
- 2P332 近赤外脳機能計測における波長差分法を用いたベースライン安定化の試み(計測))
- 指尖部皮膚表面温度の寒冷負荷試験における音楽聴取の効果 : 聴取により誘導された感情状態との相関
- 指尖部皮膚表面温度の寒冷負荷試験における音楽聴取の効果 : その心理学的変化との相関
- 円偏光放射光の発生とその応用研究