Precise Measurement of Meniscus Displacement in the Knee Joint
スポンサーリンク
概要
- 論文の詳細を見る
We present a precise method of measuring the displacement of soft tissue using a probe with a compliant needle. The displacement vector is set using two needles which are fixed in the tissue. The new method was applied to measure the displacement of a porcine meniscus in the transverse plane under joint load. The meniscus moved 0.5-1mm outward under joint load of 600 N in 2 seconds. Then, slow displacement due to creep deformation followed. The results show approximate agreement with previous predictions by computer simulation and strain measurement.