Change in Contact Conditions of Knee Joint Caused by Total Knee Replacement and Its Effect : Investigation on Two-Dimensional Model during Gait
スポンサーリンク
概要
- 論文の詳細を見る
Total knee replacement changes the shape of articular surfaces and the condition of cruciate ligaments depending on the type of artificial knee joint used. This affects the contact conditions between femur and tibia. In order to evaluate and improve the performance of artificial knee joints, it is necessary to determine the variation of contact conditions to which the components are subjected. In this study, contact conditions during gait were calculated using motion analysis, inverse dynamics and non-linear optimization methods for a two-dimensional lower limb model, and stress analysis of the fixation interfaces of tibial components was performed. Results indicated that differences in the shape of articular surfaces and the condition of cruciate ligaments led to marked differences in the contact conditions and the stress distributions at the interface. It is generally considered that these differences would affect the loosening of the components and the life of the joints.
- 一般社団法人日本機械学会の論文
- 2000-12-15
著者
-
YASUDA KAZUNORI
Department of Sports Medicine and Joint Reconstruction Surgery, Hokkaido University Graduate School
-
Yasuda Kazunori
Department Of Clinical Biomechanics Hokkaido University.
-
FUJIKI Hiroyuki
Department of Electrical Engineering, Faculty of Engineering, Kanagawa University
-
Fujiki Hiroyuki
Department Of Electrical Engineering Faculty Of Engineering Kanagawa University
-
Fujiki Hiroyuki
Department Of Mechanical Engineering Kitami Institute Of Technology
-
ISHIKAWA Hiromasa
Division of Mechanical Science, Hokkaido University
-
Ishikawa H
Division Of Mechanical Science Hokkaido University
-
Ishikawa Hiromasa
Division Of Mechanical Science Hokkaido Univ.
関連論文
- Impact of patellofemoral osteoarthritis on long-term outcome of high tibial osteotomy and effects of ventralization of tibial tubercle
- Stress shielding of patellar tendon : effect on small-diameter collagen fibrils in a rabbit model
- Anatomical Reconstruction Procedure for the Anteromedial and Posterolateral Bundles of the Anterior Cruciate Ligament
- The effect of cell-based therapy with autologous synovial fibroblasts activated by exogenous TGF-β1 on the in situ frozen-thawed anterior cruciate ligament
- Direct Measurements of Velocity Profiles in Flows of Polymer Solutions through a Rectangular Microchannel with a PDMS Surface
- Flow Simulation of Fiber Suspensions in Polymeric Fluid through Abrupt Contraction
- Biomechanical comparisons of anterior cruciate ligament : reconstruction procedures with flexor tendon graft
- Effects of Rheological Property of Coating Liquid and Withdrawal Velocity on Dip Coating Process in Manufacturing of Capsules
- Migration and Orientation of Micro-Disk Particles in a Newtonian Flow through a Slit Channel
- Tensile Properties of Collagen Fascicles in the Rabbit Patellar Tendon After Removal of the Central Third(Soft Tissue Mechanics)
- A Multi-Mode Viscosity Model and Its Applicability to Non-Newtonian Fluids
- Juvenile Blount's disease : bilateral case with asynchronous onset
- ACUTE STATIC STRETCHING REDUCES POWER OUTPUT DURING ISOTONIC MUSCLE ACTION(Proceedings of The 8^ Asian Federation of Sports Medicine Congress 2005 Tokyo)
- Effect of B-Ions Substitution in [(K_Bi_)-(Na_Bi_)](Ti-B)O_3 System with B=Zr, Fe_Nb_, Zn_Nb_ or Mg_Nb_
- B-Ion Substitution in (Pb-A)(Ti-B)O_3 Systems with A=Na_Bi_ or K_Bi_ and B=Zr, Fe_Nb_, Zn_Nb_, Mg_Nb_ or Mg_W_
- Change in Contact Conditions of Knee Joint Caused by Total Knee Replacement and Its Effect : Investigation on Two-Dimensional Model during Gait
- Contact Mechanics of Ultrahigh-Molecular-Weight Polyethylene for Artificial Knee Joint
- Constitutive Equation for Cyclic Plasticity Considering Memorization of Back Stress
- GS(6)-27(GSW0044) Interaction Between Cyclic Plasticity and Creep of Type 304 Stainless Steel
- OS10(2)-7(OS10W0040) Effect of Lead and Lead-Free Solders on Bend of Substrate
- Viscoplastic Deformation of Lead Free Solder Alloy- Experiments and Simulations
- Direct Measurements of Velocity Profiles in Flows of Polymer Solutions through a Rectangular Microchannel with a PDMS Surface
- Effects of Rheological Property of Coating Liquid and Withdrawal Velocity on Dip Coating Process in Manufacturing of Capsules