Simultaneous Measurement of [Ca^2+]_i and Membrane Potential under Mechanical or Biochemical Stimulation(Proceedings of the Switzerland-Japan Workshop on New Directions in Cellular and Tissue Biomechanics)(Special Issue on Bioengineering)
スポンサーリンク
概要
- 論文の詳細を見る
In human umbilical endothelial cells (HUVEC), mechanical stress is known to induce transients of [Ca^2+]_i that lead to the regulation of vascular functions in vivo. The transmembraneous influx of Ca^2+ is thought to be mediated by voltage-dependent ion channels or stretch-activated ion channels. In order to elucidate the correlation of [Ca^2+]_i and membrane potential under mechanical stress, the influences of mechanical or biochemical stimulation on endothelial cells stained with both fura-2 and DiBAC_4 (3) were studied in vitro, by constructing an imaging system that could capture four kinds of fluorescence images simultaneously at real-time. In the application of thrombin, [Ca^2+]_i transients were accompanied with preceding depolarization, while mechanical stress that were loaded on a single cell with a micropipette did not evoke dramatic changes of membrane potential. These results indicate that the signaling pathway initiated by mechanical stress could be independent of electrochemical activation, and different from that by biochemical stimulation in HUVEC.
- 一般社団法人日本機械学会の論文
- 2002-12-15
著者
-
TATEISHI Tetsuya
Department of Applied Chemistry, Tokyo University of Science
-
Ushida Takashi
Department Of Mechanical Engineering Graduate School Of Engineering The University Of Tokyo
-
TATEISHI Tetsuya
National Institute for Advanced Interdisciplinary Research
-
Tateishi Tetsuya
Biomaterials Center National Institute For Material Science
-
Tateishi Tetsuya
Crest Jst:univ. Tokyo
-
Tateishi Tetsuya
Tissue Engineering Research Center National Institute Of Advanced Industrial Science And Technology:
-
Tateishi Tetsuya
Mechanical Engineering Laboratory Agency Of Industrial Science And Technology Ministry Of Internatio
-
Sano Minoru
Department Of Mechanical Engineering Graduate School Of Engineering The University Of Tokyo
-
Tateishi T
National Inst. Advanced Interdisciplinary Res. Ibaraki Jpn
-
Tateishi T
Department Of Mechanical Engineering Graduate School Of Engineering The University Of Tokyo
-
IMURA Katsuaki
Department of Mechanical Engineering, Graduate School of Engineering, The University of Tokyo
-
Tateishi Tetsuya
Department Of Applied Chemistry Tokyo University Of Science
-
Tateishi Tetsuya
Biomaterials Center National Institute For Materials Science
-
Tateishi Tetsuya
Biomedical Engineering Laboratory (tateishi & Ushida Laboratory) Department Of Mechanical Engine
-
Tateishi Tetsuya
Graduate School Of Engineering University Of Tokyo
-
Tateishi Tetsuya
Mechanical Engineering Laboratory Agency Of Industrial Science And Technology Ministry Of Internatio
-
Imura Katsuaki
Department Of Mechanical Engineering Graduate School Of Engineering The University Of Tokyo
関連論文
- Hepatocyte Spheroids Underlayered with Nonparenchymal Cells for Biomedical Applications
- Effects of Mo and Pd on Corrosion Resistance of V-Free Titanium Alloys for Medical Implants
- Corrosion Resistance and Mechanical Properties of New Titanium Alloys for Centrifugally Cast Dental Implants
- Corrosion Resistance of Implant Alloys in Pseudo Physiological Solution and Role of Alloying Elements in Passive Films
- Effects of Heat Treatment on Mechanical Properties and Corrosion Fatigue Strength in Physiological Saline Solution of New Titanium Alloys for Medical Implants
- Evaluation of hydroxyapatite-coated screws for lumbar spine fixation in dogs
- Evaluation of cylindrical interbody fusion devices in canine lumbar spine : Comparison of fixation stiffness in devices with and without hydroxyapatite coating
- Real-time evaluation of hemocompatible materials by substandard human blood for transplantation by blood bank
- Real-time Evaluation of Hemocompatible Materials by Human Platelets as an Alternative to Animal Experimentation
- Real-time evaluation of hemocompatible materials
- Effects of Ti, Al and V Concentrations on Cell Viability
- Localization of Osteopontin-GFP Fusion Proteins in Osteoblastic Cells : Dual-channel Confocal Imaging of GFP Fusion Proteins and Organelles
- C1-C2 Intra-articular Screw Fixation for Atlantoaxial Posterior Stabilization
- Evaluation of fixation of various screws in the lumbar vertebrae of dogs
- Novel Culture Techniques for Bone Tissue Engineering
- Bone Tissue Engineering Using Marrow Cells
- Cultured Bone Transplantation in Combination with Gene Transfer Techniques
- Effects of Metallic Concentrations Other Than Ti, Al and V on Cell Viability
- Thermoelastic Femoral Stress Imaging for Experimental Evaluation of Hip Prosthesis Design
- Tissue-engineered skin using aggregates of normal human skin fibroblasts and biodegradable material
- Effects of Aluminum Oxide Film on Fibroblast L929 and V79 Cell Viabilities
- Biodegradable porous scaffolds for tissue engineering
- Hybrid Scaffolds for Tissue Engineering
- Fabrication of PLGA-Collagen Hybrid Sponge
- Simultaneous Measurement of [Ca^2+]_i and Membrane Potential under Mechanical or Biochemical Stimulation(Proceedings of the Switzerland-Japan Workshop on New Directions in Cellular and Tissue Biomechanics)(Special Issue on Bioengineering)
- ASSESSMENT OF PERMEABILITY AND HYDRATION OF TISSUE-ENGINEERED CARTILAGE USING DIFFUSION-MRI(3A3 Cellular & Tissue Engineering & Biomaterials III)
- Assessment of Fixed Charge Density in Regenerated Cartilage by Gd-DTPA-enhanced MRI
- Influence of Structure and Composition on Dynamic Viscoelastic Property of Cartilaginous Tissue : Criteria for Classification between Hyaline Cartilage and Fibrocartilage Based on Mechanical Function(Bioengineering)
- Dynamic Visco-Elastic Property of Chondrocyte/Agarose Constructs and Its Comparison with That of Native Cartilage(Micro- and Nano-biomechanics)
- Hepatocyte Spheroids Underlayered with Nonparenchymal Cells for Biomedical Applications
- Evaluation of hydroxyapatite coating screw at extraction in the canine lumbar spine
- High Time Resolution Time-Lapse Imaging Reveals Continuous Existence and Rotation of Stress Fibers under Cyclic Stretch in HUVEC
- Polyfunctional Scaffolds for Tissue Engineering