圧電ファンの性能試験(G05-10 流体機械(2),G05 流体工学部門一般講演)
スポンサーリンク
概要
- 論文の詳細を見る
Performance tests of small piezoelectric fan were carried out in order to clarify the effect of fan casing. Test fan was made of piezo ceramics and polyestel film with dimensions of 40mm×24mm and its natural frequency was about 100Hz. Configurations of outlet casing were designed based on the velocity field around the vibrating film measured by PIV method. As a result this piezoelectric fan with suitable outlet casing could produce air flow rate of 35 L/min and static pressure of 6.0Pa at maximum fan efficiency point. It was found that width and configuration of outlet casing exerted a great influence on the fan performance, because the leaned flow discharged form the vibrating film was mixed and uniformed in there space.