Stability Measurement of the 0.633 μm Line in a CH_4-Locked 3.39 μm He-Ne Laser
スポンサーリンク
概要
- 論文の詳細を見る
Optical heterodyne measurement of frequency stability of the 0.633 μm line in dual stabilization with the 3.39 μm line was carried out. The best stability in terms of Allan variance was 4.14×10^<-11> for averaging time τ=1 s and the long-term stability was 3.14×10^<-10> for τ=100 s. Decrease of the long-term stability appears mainly to be attributable to a difference of the temperature coefficients of the Brewster windows at each wavelength.
- 社団法人応用物理学会の論文
- 1980-06-05
著者
-
Musha Toshimitsu
Department Of Applied Electronics Tokyo Institute Of Technology
-
NAKAZAWA Masataka
Department of Applied Electronics, Tokyo Institute of Technology
-
Nakazawa Masataka
Department Of Applied Electronics Tokyo Institute Of Technology
関連論文
- 1/f Fluctuations in LiCl Solution
- ESTIMATION OF THE EQUIVALENT CARDIAC DIPOLE : THE IV CONFERENCE ON VECTORCARDIOGRAPHY
- Correlation between Frequency Fluctuations of a Quartz Oscillator and Temperature Fluctuations
- Model Study of Spontaneous Discharge Fluctuations of a Membrane Potential
- Traffic Current Fluctuation and the Burgers Equation
- The 1/f Fluctuation of a Traffic Current on an Expressway
- 1/f Spike Discharge Interval Fluctuations of DOPH Millipore Membrane
- Phase Oscillation in Fiber Interferometer Caused by Light Impulse
- Al-coated variable thickness Pb microbridge.
- Clustering Poisson Process and 1/f Noise
- 1/f Fluctuations in the Dielectric Response of Triglycine Sulfate : Thermal and Statistical Properties
- 1/f Fluctuations of Phonon Energy in Water
- Power Spectral Density Estimation of Light Intensity Fluctuations in Photon Counting
- Observation of Saturated Absorption of the 3.39 μm Line in an External CH_4 Cell
- 1/f Conductance Fluctuations in Aqueous Ionic Solution
- Determination of the Agglutination Reactions Using Power Spectral Analysis of the Depolarized Light Intensity Fluctuations Scattered from Magnetic Particles
- Stability Measurement of the 0.633 μm Line in a CH_4-Locked 3.39 μm He-Ne Laser
- Energy and Power Flow of a Wave in a Moving Dispersive Medium
- Stability of FM-Eliminated 3.39 μm He-Ne/CH_4 Laser
- A New Microbridge with an Improved I-V Curve
- Motion of Equivalent Electric Dipole to Cardiac Activity Estimated from Body Surface Potentials
- Moving multiple dipole model for cardiac activity.
- A proposal for the standardization of body surface potential mapping (BSPM) systems.
- Computer simulation of the Wolff-Parkinson-White syndrome utilizing a human heart model.