Line Shift Method for Phosphor Temperature Measurements
スポンサーリンク
概要
- 論文の詳細を見る
Two possible approaches to spectroscopic measurements of the internal temperature of Y_2O_2S: Eu are discussed. Methods based on relative Eu^<3+> fluorescence line intensities are found either to be insufficiently sensitive or to suffer from unavoidable experimental difficulties. The method which is adopted exploits the quadratic shift of the Eu^<3+> ^5D_0→^7F_0 transition energy with temperature. Controlled-temperature UV- and CR-excited fluorescence measurements establish the temperature calibration, which is then used to obtain the operating temperature of phosphor screens in a demountable CR excitation apparatus and in a tricolor CRT.
- 社団法人応用物理学会の論文
- 1976-12-05
著者
-
Yoshioka Taisuke
Color Television Development Division Sony Corporation
-
KUSAMA Hideo
Color Television Development Division, Sony Corporation
-
SOVERS Ojars
Color Television Development Division, Sony Corporation
-
Kusama Hideo
Color Television Development Division Sony Corporation
-
Sovers Ojars
Color Television Development Division Sony Corporation