乾燃室丸ボイラーの計測結果
スポンサーリンク
概要
- 論文の詳細を見る
This research was carried out, by the request of the Nippon Kaiji Kyokai, on the first all-welded dry combustion boiler with two furnaces in Japan, which was manufactured at the Innoshima yard. In order to obtain the data for the design, manufacturing, inspection and operation of such an all-welded boiler, authors measured the deformations and stresses of the boiler and also checked. whether it would yield under the test water pressure required by the rules or not. Although authors had not enough time to measure the all of the scheduled points of the boiler, because it was to be fitted to a new ship before long, authors could clear up several facts as follows. (1) Even under the required pressure, any sign of the yielding phenomenon was not noticed at any part of the boiler. (2) Therefore, as far as it concerns the boiler tested, it is not necessary to provide any longitudinal stay to strengthen the water-containing part formed by the flues and shell plate. (3) At the water-containing part above mentioned, it was observed that the ehd plate having a manhole reinforced by flanged plate was stronger in the elastic region than the other not having it, unless there were any other factors. (4) The stress which occurs at the flanged part of the end-plate edge shows the highest value at the center of the curved part, however this highest value of each curved section varies in accordance with the unsupported area of the flat plate to which the curved part joins. (5) It will be seen that holes provided for the water tubes of the rear end-plate do not affect the elastic stresses of the end-plate. (6) The welded longitudinal joint of shell plate, which is annealed after welding, is considered to be stronger than the riveted joint, unless the extreme change of curvature occurs in it while annealing.
- 社団法人日本船舶海洋工学会の論文
- 1955-06-25
著者
関連論文
- 圧力容器の強さと設計(材料力学(圧力容器))
- だ円形胴板の実験式と設計法
- 最近検討された圧力容器の二, 三の設計法について(材料力学(圧力容器))
- だ円形胴板の強さについて : その2,理論的考察
- だ円形胴板の強さについて : その2,理論的考察
- 平板のドッグステーによる補強効果について
- 平板のドッグステーによる補強効果について
- 偏心円孔を有するだ円形平板の強さ
- 偏心円孔を有するだ円形平板の強さ
- だ円形胴板の強さについて : その1,応力およびたわみに及ぼす胴板長さの影響
- だ円形胴板の強さについて : その1,応力およびたわみに及ぼす胴板長さの影響
- 機関車形ボイラの外火室を補強する横ステーの強さの研究
- 機関車形ボイラの外火室を補強する横ステーの強さの研究
- ボイラ胴板の有穴部に設ける補強板の効果
- 乾燃室丸ボイラーの計測結果
- ボイラ平鏡板の強さ (その7) : 偏心2円筒によりささえられた平鏡板の応力 : 厳密解と近似解との数値計算値の比較
- ボイラ平鏡板の強さ(その7) : 偏心2円筒によりささえられた平鏡板の応力
- ボイラ平鏡板の強さ(その6) : 胴板およびこれと偏心せる炉筒によりささえられた平鏡板の強さ
- ボイラ平鏡板の強さ(その5) : 平鏡板に設けたマンホール補強フランジの高さ
- ボイラ平鏡板の強さ(その6) : 胴板およびこれと偏心せる炉筒によりささえられた平鏡板の強さ
- ボイラ平鏡板の強さ(その4) : 胴板および炉筒または煙突管によりささえられた平鏡板の強さ
- ボイラ平鏡板の強さ(その3) : 平鏡板のフランジわん曲部における応力
- ボイラ平鏡板の強さ(その5) : 平鏡板に設けたマンホール補強フランジの高さ
- ボイラ平鏡板の強さ(その4) : 胴板および炉筒または煙突管によりささえられた平鏡板の強さ
- ボイラ平鏡板の強さ(その3) : 平鏡板のフランジわん曲部における応力
- ボイラ平鏡板の強さ(その2) : 相隣れる両炉筒と胴板との間の充水部平板の強さ
- ボイラ平鏡板の強さ(その1) : 相隣れる両炉筒と胴板との間の充水部平板の強さ
- 鍛造工場における蒸気蓄勢器の利用