Simulator-assisted Setting of Scan Protocols for X-ray CT : Development and Clinical Usefulness of the Scan Plan Simulator
スポンサーリンク
概要
- 論文の詳細を見る
To assist in the selection of complicated computed tomography (CT) scan protocols and to obtain stable image SD values, prototype "Scan Plan Simulator" software with the following functions was developed and evaluated. 1) The image SD value that will be obtained in actual scanning is estimated by entering the patient's body size and scan protocol, after which a simulated image is displayed so that the estimated image SD value can be checked. The exposure dose can also be estimated in the Scan Plan Simulator. 2) The appropriate tube current is automatically set by entering the required image SD value. We evaluated the accuracy of the Scan Plan Simulator by comparing the simulation results with the image SD values and exposure dose obtained in actual scanning and assessed the usefulness of this method using Monte Carlo simulation based on body thickness data obtained in clinical examinations. The results showed that the Scan Plan Simulator not only stabilizes image SD by minimizing the effects of body size but also permits the exposure dose to be reduced by optimizing tube current.
- 公益社団法人日本放射線技術学会の論文
- 2006-01-20
著者
-
塚越 伸介
東芝メディカルシステムズ(株)
-
Johkoh Takeshi
Osaka University Faculty Of Medicine School Of Allied Health Sciences
-
塚越 伸介
東芝メディカルシステムズ株式会社ct開発部
-
OTA TAKAMASA
Embedded Systems Solutions Division, Toshiba Information Systems (Japan) Corporation
-
OKUMURA MIWA
CT Systems Development Department, Toshiba Medical Systems Corporation
-
MURAMATSU YOSHIHISA
Department of Radiology, National Cancer Center Hospital EAST
-
Ota Takamasa
Embedded Systems Solutions Division Toshiba Information Systems (japan) Corporation
-
Okumura Miwa
Ct Systems Development Department Toshiba Medical Systems Corporation
-
Muramatsu Yoshihisa
Department Of Radiology National Cancer Center Hospital East
関連論文
- 65 生ノイズ加算シミュレータによるCT用自動露出機構(CT-AEC)の画質レベル設定方法(CT検査 基礎・自動露出(AEC),一般研究発表,日本放射線技術学会 第34回秋季学術大会)
- CT用自動露出機構 (CT-AEC) の臨床応用 : ノイズ加算シミュレータの初期的検討(CT検査 被ばく低減3, 一般研究発表予稿集, 日本放射線技術学会第33回秋季学術大会)
- MSCTを用いた胸部CT検診におけるCT用自動露出機構の有用性(第32回秋季学術大会放射線防護管理関連演題発表後抄録, 第61回総会学術大会放射線防護分科会)
- 235 MSCTを用いた胸部CT検診におけるCT用自動露出機構の有用性(CT検査 線量管理)(一般研究発表)(第32回秋季学術大会)
- 最新の被ばく低減技術(マルチスライスCTの最先端技術の臨床応用)
- Simulator-assisted Setting of Scan Protocols for X-ray CT : Development and Clinical Usefulness of the Scan Plan Simulator
- 量子ノイズ低減化フィルタ(量子フィルタ)による低被ばく時の画質向上(ワークショップ-よりよい撮影技術を求めて(その73)-「腹部CT検査のエビデンスガイドライン」)(テーマB:CT「腹部CT検査のエピデンスガイドライン」)
- X線CT : 第2回 : CT画像の基本と画像表示
- New Method of Evaluating Edge-preserving Adaptive Filters for Computed Tomography (CT) : Digital Phantom Method