概要
- 論文の詳細を見る
This paper deals with the γ ray intensity distributions on the plane normal to the central ray by the one type Telecobalt apparatus (Type RI 103,300C, 2cm^2φ, wafers type). Method : The γ ray dose was calculated by means of film method, corrected by Siemens-dosemeter. One of the 2 sheets of industrial film type RR was placed holizontally on the surface of the water phantom (20×30×20cm^3), and the other one in the 10cm depth. Results : 1) It seems the intensity distributions are nearly homogeneous within 5×5cm^2 diaphram width. It is observed that relative intensity of the peripheral area to the central area at the region of the umbra are more than 90%. In the penumbra area diminished the intensity to 80〜50%. But the shape of irradiation fields are seemed almost rectangular, similarly to th shape of diaphram. 2) If the diaphragm width are more than 6×6cm^2,the diminishments of intensity at the corners of the irradiation fields are observed (from 80% to 60% of center intensity). This matter is same in the umbral area as the penumbral area. According to this facts, the shape of irradiation fields are jnst like round, in spite of rectangular diaphragm. 3) It is caused by the shape and geometrical structure of the cylindrical hole of the rotating shutter that the isodose curves are not rectangular at large irradiation fields. 4) To perform the shape of irradiation fields rectangular similar to the diaphrgm pattern are there some improvements necessary. (1) To widen the diameter of cylindrical hole of the rotating shutter. (2) To make alternation of shape of the cylindlical hole to the rectangle. (3) To the shorten the length of the hole of the rotating shutter.
- 公益社団法人日本放射線技術学会の論文
- 1965-04-25
著者
関連論文
- 155.血漿中β-ThromboglobulinおよびPlatelet Factor4の基礎的検討ならびに臨床的検討 : 特に高血圧患者における有用性(第41回総会会員研究発表)(RI-4 試料測定-4)
- 104.RIイメージング規格化のある試み(第2報)(第38回総会会員研究発表)(RI-1 体外測定-1)
- 418.RIイメージング規格化へのある試行(第37回総会 会員研究発表)(RI-13データ処理2)
- 94.脳室スキャニングの技術的諸問題
- 430.自動EF算出における画像処理条件の影響 : 心動態ファントム実験による検討 : RI-16 : 心機能
- 159.心電図同期心プールシンチグラフィ用試作心フアントムの検討(第40回総会会員研究発表)(RI-2 体外測定-1)
- 195.RCTによる肝重量推定の基礎研究(第39回総会会員研究発表)(RI-9 ECT-2)
- 185.呼吸同期^Xeイメージングの試み(第39回総会会員研究発表)(RI-7 体外測定-4)
- 座長集約23
- 235.RIAにおける精度管理 : オンラインデータ処理の検討(第35回総会会員研究発表)(RI9試料測定2)
- 160.ラジオイムノアッセイの精度管理(RI6試料測定)(第33回総会会員研究発表)
- 190.甲状腺機能検査および基礎代謝の検査結果の統計的観察
- テレコバルト-60の照射方向に垂直な平面の線量分布
- 82.テレコバルトの照射方向に垂直な平面の線量分布
- 1.水洗時間短縮化の一方法について(東京都支部)
- 82〕 遮蔽格子の縞目に関する2,3の考察
- 82)テレコバルト照射の深部百分量率表及び深部等線量曲線(第15回学会会員研究発表)
- 246.PEG法における血清蛋白濃度の影響(第38回総会会員研究発表)(RI-10 試料測定-4)