Calculation of longitudinal conversion loss and input impedance for indoor AC mains line considering high-speed PLC
スポンサーリンク
概要
- 論文の詳細を見る
The power line communication (PLC) system should be investigated with respect to the influence on electromagnetic environments. Longitudinal conversion loss (LCL) and input impedance are important parameters for evaluating the influence because they are closely related to the radiated, conducted, and inducted emission. An indoor AC mains system consisting of electrical equipment and an AC mains line was modeled by four-port networks, and the LCL and the input impedance were calculated. The parameters of the four-port networks were determined from theory and measurement. The analytical model was examined using a simple network and the results show that the calculated values agreed with the measured ones. The LCL and the input impedance were investigated at the AC mains port in some existing buildings, and the measured results almost agreed with the calculated results derived from the indoor AC mains system model
- 社団法人電子情報通信学会の論文
- 2005-09-01
著者
-
YAMANE Hiroshi
NTT Facilities Inc.
-
KUWABARA Nobuo
Kyusyu Institute of Technology
-
Akiyama Yoshiharu
Ntt Corp. Musashino‐shi Jpn
-
Akiyama Yoshiharu
Ntt Energy And Environment Systems Lab. Tokyo Jpn
-
Kuwabara Nobuo
Department Of Electrical Engineering Kyushu Institute Of Technology
-
A.K.M. Mahbub
Department of Electrical Engineering, Kyushu Institute of Technology
-
MAKI Masahiro
Matsushita Electric Industrial Co. Ltd., Multimedia Development Center
-
YAMANE Hiroshi
NTT Energy and Environment Systems Laboratories, NTT Corporation
-
Yamane Hiroshi
Ntt Energy And Environment Systems Laboratories Ntt Corporation
-
A.k.m. Mahbub
Department Of Electrical Engineering Kyushu Institute Of Technology
-
Kuwabara Nobuo
Dept. Of Electrical Engineering And Electronics Kyushu Institute Of Technology
-
Kuwabara Nobuo
Kyushu Institude Of Technology
-
Kuwabara Nobuo
Department Of Electrical Engineering And Electronics Kyushu Institute Of Technology
-
Maki Masahiro
Matsushita Electric Industrial Co. Ltd. Multimedia Development Center
-
Rashid AKMAM
Department of Electrical Engineering, Kyushu Institute of Technology
-
Kuwabara N
Department of Electrical Engineering, Kyushu Institute of Technology
-
Maki M
Matsushita Electric Industrial Co. Ltd., Multimedia Development Center
-
Akiyama Y
NTT Energy and Environment Systems Laboratories, NTT Corporation
-
Yamane H
NTT Energy and Environment Systems Laboratories, NTT Corporation
関連論文
- Effect of PLC Signal Induced into VDSL System by Conductive Coupling
- Calculation of longitudinal conversion loss and input impedance for indoor AC mains line considering high-speed PLC
- Calculation of Electromagnetic Field Emitted from UTP Cable by Moment Method from 0.3GHz to 2GHz
- Macroscopic visualization of a radiated emission source using cylindrically scanned electric field amplitude data
- Comparison of site attenuation analysis results between FDTD and ray-tracing method using compact anechoic chamber
- A Two-Dimensional Clustering Approach to the Analysis of Audible Noises Induced at Telephone Terminals(Electromagnetic Compatibility (EMC))
- Investigation of Radiated Emission Characteristics of Balanced Cable by Using Analysis Method that Takes a Balance-Unbalance Conversion Factor into Consideration
- Effect of PLC Signal Induced into VDSL System by Conductive Coupling
- Method of Evaluating Shielding Effect of Enclosure Using Disc-Cone Antenna Operated by O/E Converter from 1GHz to 8GHz
- FOREWORD