全帯域レベル値L_cとL_Aとを用いた床衝撃音の解析と評価
スポンサーリンク
概要
- 論文の詳細を見る
Acoustical properties of impact sound generated by the standard tapping machine can simply be characterized by two factors the maximum band level and the center frequency concerned with it, since the spectra of impact sound obtained in various cases of floor structures are very similar to each other. A method based on this principle for analyzing and evaluating the impact sound insulation of floors is studied theoretically. It is found that the pair of the values of L_C and L_A which can be measured with a sound level meter is also applicable for analyzing the acoustical factors above mentioned. A graphic method where a certain pair of values of L_C and L_A locates a point is convenient for evaluating the results obtained in field measurements and assessing the impact sound insulation of floors. Assuming the standardized spectrum pattern of impact sound, it is possible to draw the contour lines for rating on this diagram according to any existing standard which needs the frequency analysis of impact sound generated by the standard source.
- 社団法人日本音響学会の論文
- 1980-02-01
著者
関連論文
- 第11回国際音響学会議(11th ICA)
- ステージ上の音響効果 (最近のホール音響)
- 低周波音域暴露実験室の構造と音響特性 (<特集>最近の各方面の音響設備)
- 建物の遮音設計
- 全帯域レベル値L_cとL_Aとを用いた床衝撃音の解析と評価
- 床衝撃音改善特性に対する表面仕上げ材料の厚さと硬度との影響について
- 表面仕上げ材による床衝撃音の低減効果
- 床衝撃音評価に用いる測定計器について
- 録音用人工頭の製作における耳介の個人的形状の重要性について
- インターノイズ74報告
- インターノイズ74(その1)
- 呉市民会館ホールの音響について
- 一重構造体の透過損失について : 遮音構造の研究II
- 透過損失測定用新残響室について : 遮音構造の研究I
- 粉末図形による模型室内音場分布の図示
- 1. 板の透過損失について : 遮音構造の研究I
- 超低音再生の一方法 (オ-ディオと建築)
- 遮音特性と遮音機構--素面あるいは内装構造をともなった一重壁の場合 (遮音材料と構法)
- 音響評価における境界値の統計的抽出と応用 (現場における心理評価-最近の騒音問題を中心に-)