Impulsive low-frequency noise generation by a 15m diameter horizontal axis wind turbine generator with downwind configuration
スポンサーリンク
概要
- 論文の詳細を見る
Horizontal axis wind turbine(HAWT)with downwind rotor location is well known to generate an impulsive low-frequency noise. Large-scale downwind machines caused several low-frequency noise problems in overseas countries. This paper describes firstly measured results of the noise generated by a 15 m diameter HAWT ・WINDMEL. ・ Generation of an impulsive low-frequency noise by the downwind WINDMEL has been ascertained in the current measurement, though it was of a rather low level. In case of the upwind WINDMEL, generation of this noise could not be ascertained. Next, the predictive calculation of an impulsive low-frequency noise is carried out based on an available method. Namely, assumptions and cautions required for the predictive calculation are presented and discussed. Furthermore, applicability of the calculation method is discussed based on the comparisons between the calculated results and the measured data.
- 社団法人日本音響学会の論文
著者
-
Kawamura Shunji
Mechanical Engineering Laboratory
-
YAMANE Takashi
Mechanical Engineering Laboratory
-
Nii Yoshinori
Mechanical Engineering Laboratory
-
Yamane T
Mechanical Engineering Lab. Ibaraki Jpn
-
Gotanda Tetsuo
Mechanical Engineering Laboratory,Agency of Industrial Science and Technology,Ministry of Internatio
-
Matsumiya Hikaru
Mechanical Engineering Laboratory,Agency of Industrial Science and Technology,Ministry of Internatio
-
GOTANDA Tetsuro
Mechanical Engineering Laboratory
-
Matsumiya H
National Inst. Advanced Industrial Sci. And Technol. Tsukuba Jpn
-
Matsumiya Hikaru
Mechanical Engineering Laboratory
関連論文
- Identification of Nonlinear Multi-Degree-of-Freedom Systems : Identification Under Noisy Measurements
- Identification of Nonlinear Multi-Degree-of-Freedom Systems : Presentation of an Identification Technique
- 139 Design of An Axial-type Self-bearing Motor for Axial Pump
- Impulsive low-frequency noise generation by a 15m diameter horizontal axis wind turbine generator with downwind configuration
- Vibration Characteristics of an Experimental Wind Turbine with a 15 m Teetered Rotor
- Acoustic noise emission from 15m diameter horizontal axis wind turbine generator with downwind configuration
- Coupled Rotor/Tower Stability Analysis of Horizontal-Axis Wind Turbines : Vibration, Control Engineering, and Engineering for Industry, New materials, new energy, biotechnology, electronics, etc.
- Flow Visualization Measurement for Shear Velocity Distribution in the Impeller-Casing Gap of a Centrifugal Blood Pump
- The Performance of Slotted Blades in Cascade
- Fluid Dynamic R & D of a Closed-type Centrifugal Blood Pump Utilizing Flow Visualization