Three-component Velocity Measurements in Turbulent Flows Using a Technique of Rotating Probe with an Inclined Hot-Wire
スポンサーリンク
概要
- 論文の詳細を見る
A technique has been developed to measure three components of mean velocity, six components of the Reynolds stress, ten components of the triple correlation, and fifteen components of the quadruple correlation of fluctuating velocity in steady turbulent flow using Hot-Wire Anemometry(HWA). The hot-wire signal was acquired by rotating a single inclined hot-wire probe toward a number of spatial orientations at the same location in a turbulent flow-field. Velocity information has been computed by decomposing the response equation for the effective velocity of the hot-wire probe.
- 一般社団法人日本機械学会の論文
- 1998-02-15
著者
関連論文
- Posterior C1-2 Fixation With Cancellous Screw and Rod System for Retro-odontoid Pseudotumor Associated With Chronic Atlantoaxial Subluxation : Technical Note
- Methionine positron emission tomography for differentiation of recurrent brain tumor and radiation necrosis after stereotactic radiosurgery : In malignant glioma
- Primary Intramedullary Spinal Cord Germinoma : Diagnostic Challenge and Treatment Strategy
- Importance of Fixation Angle in Posterior Instrumented Occipitocervical Fusion
- Primary Epidural Peripheral Primitive Neuroectodermal Tumor of the Thoracic Spine : Case Report
- Intratumoral Hemorrhage of Spinal Schwannoma of the Cauda Equina Manifesting as Acute Paraparesis : Case Report
- Percutaneous Transluminal Angioplasty and Stent Placement for Subclavian Steal Syndrome With Concomitant Anterograde Flow in the Left Internal Mammary Artery Graft for Coronary Artery Bypass : Case Report
- Discrepancy Between [^F]fluorodeoxyglucose and ^C-methionine Positron Emission Tomography Findings in Sturge-Weber Syndrome(Case Report)
- Interictal Patterns of Cerebral Glucose Metabolism, Perfusion, and Magnetic Field in Mesial Temporal Lobe Epilepsy
- Evaluation of treatment effects in brain abscess with positron emission tomography : Comparison of fluorine-18-fluorodeoxyglucose and carbon-11-methionine
- Magnetic Resonance Imaging and [^C]Methyl-L-Methionine Positron Emission Tomography of Fibrous Dysplasia : Two Case Reports
- Surgery of Spinal Nerve Sheath Tumors Originating From C1 or C2 of High Cervical Spine : Technical Note
- D102 Three-Components Velocity Measurement in Unsteady Turbulent Pipe Flows Using a Non-Orthogonal Triple-Sensors Probe(Flow measurement)
- Magnetic Resonance Imaging of Brain Abscess With Hemorrhage : Implications for the Mechanism of Hemorrhage
- Three-component Velocity Measurements in Turbulent Flows Using a Technique of Rotating Probe with an Inclined Hot-Wire
- Drag Reduction Effects of Micro-Bubbles in Straight and Helical Pipes
- Spinal Hemangioblastoma of Cauda Equina Origin Not Associated With Von Hippel-Lindau Syndrome
- Examination of Various Estimation Equations for Drag Force by Using Immersed Boundary Method
- Primary Intramedullary Langerhans Cell Histiocytosis of the Thoracic Spinal Cord:—Case Report—
- C2 Nerve Root Resection to Achieve Safe and Wide Exposure of Lateral Atlantoaxial Joints in Posterior C1-2 Instrumented Fixation: Technical Note
- Primary Intramedullary Langerhans Cell Histiocytosis of the Thoracic Spinal Cord -Case Report-
- Assessment of Cervical Spondylotic Myelopathy Using Diffusion Tensor Magnetic Resonance Imaging Parameter at 3.0 Tesla