ガラス管振動子による微小密度差の測定
スポンサーリンク
概要
- 論文の詳細を見る
At the measurement of liquid density, it is generally an important problem how the error influenced by temperatures can be decreased. As one of the countermeasures to it, an instrument was devised to measure the density diffence of liquid samples by using two vibrators of glass tube. The operating principle is as follows; a standard liquid of density is poured into one of the vibrators and a sample is poured into another, each period of vibration is measured with am electric counter, then the difference of density between the standard liquid and the sample is got from that of the period of vibration. By putting two vibrators in the same bath stirring water and measuring their values at the same time. the error was adle to be less than that of the single vibrator. As the result the density difference of water samples was measured with better precision than l ppm, only by controlling the room temperature at 20℃±0.5℃.
- 社団法人日本時計学会の論文
- 1977-09-20
著者
関連論文
- 時計ケースの材料及び加工
- 『最近のCIM動向と諸問題』
- 『リチウム電池の最近の動向』
- 時計用ステップ・モーター
- 時計用水晶を考える
- 「水晶振動子の最近の動向」
- 「プラスチック射出成形のCAE」
- 超精密プラスチック製品の成形・生産
- 「時計生産に於ける自動組立」
- 耐圧形振動式密度計によるLPGの密度測定
- 重力加速度絶対測定における標準尺の測温とg値への影響 : 計測
- 外部同期信号による自動車用タイヤの回転数測定
- 自動車タイヤの有効周の測定装置
- LPG密度浮ひょうの圧力と気体の浮力に関する補正
- 標準尺落下による重力加速度の絶対測定における系統誤差の処理について
- ガラス管振動法による水の密度差の精密測定
- 浮力法によるLPG密度の精密測定
- 最小二乗法における計算精度 : 計測
- 重力加速度の絶対測定のデータ処理 : 測定技術および計測標準
- リンク機構をもつコイルばねの振動特性
- 時計台の鐘の音
- 私の提案
- 科学万博に展示された時計について
- ガラス管形振動式密度計の装置定数の温度特性
- ガラス管振動子の温度特性
- ガラス管振動子による微小密度差の測定
- 弾性振動を利用した流体の密度測定
- 新しい重力加速度の絶対測定装置
- 光電検出によるテンプの周期測定
- 新しい重力加速度の絶対測定装置