計量研究所のタイム・スケールの国際比較結果と周波数変動要因の解析
スポンサーリンク
概要
- 論文の詳細を見る
Results of international time comparison of clocks in the National Research Laboratory of Metrology (NRLM) have been published since 1980 in the Annual Reports of the Bureau International de l'Heure (BIH) , in UTC (BIH) minus UTC (NRLM). According to these results, it is recognized that the frequency stability of NRLM clocks has been improved from year to year, while the environmental conditions of the clocks in room temperature and relative humidity have been also improved since 1980. In Order to analize the instability sources, data in the BIH Annual Reports and those of domestic time comparison made by the TV method are used. After eliminating separable factors included in these data, it is found that the most part of instability is attributed to the international time comparison, but not to the NRLM clocks themselves due to imperfection of the environmental conditions. Instability of the former is estimated as 3.5×l0^(-13)/√τ (l0 days ≦ τ ≦ 80 days), and the latter as 0.6×10^(-13)/√τ (7 days ≦ τ ≦ 100 days) for 1983.
- 社団法人日本時計学会の論文
- 1985-09-20
著者
関連論文
- 計量研究所のタイム・スケールの国際比較結果と周波数変動要因の解析
- 時刻の精密比較測定データ取得装置の自動化
- 時刻比較測定デ-タ取得装置の自動化
- テレビ電波による時計比較測定の安定度--共通送信アンテナ利用の場合
- 長波標準電波の時刻コードのデコーダ
- テレビジョン電波による時計の精密比較.
- 重力加速度絶対測定における標準尺の測温とg値への影響 : 計測