Chaos-based Quantitative Health Evaluation and Disease State Estimation by Acceleration Plethysmogram
スポンサーリンク
概要
- 論文の詳細を見る
Acceleration plethysmogram (APG) is applied noninvasively and is used mainly for estimation of arteriosclerosis and blood vessel age. However, physicians of the Chinese school, from ancient times, have applied sphygmopalpation for health examination. This is because APG sensitively reflects the degree of cardiac output, distensibility of the peripheral blood vessels, arteriosclerosis, and the autonomic system. From our previous research employing the recurrence plots method as a chaotic analysis approach on APG for quantitative health examination, it was possible to evaluate healthy and disease states with an accuracy rate of over 86%. But the APG with small amplitude and normal topological structure is evaluated as disease. Based on this result, we carried out new research on classification of disease state; not disease name, and appropriate evaluation for APG with small amplitude and normal topological structure. As a result of our new research, all examinees were estimated quantitatively from the viewpoint of homeodynamical and hemorheological state.
- 日本知能情報ファジィ学会の論文
- 2003-10-15
著者
-
UCHIDA Ichiro
Department of Anesthesiology, Graduate School of Medicine, Osaka University
-
Uchida Ichiro
Department Of Biological Science Faculty Of Science Kumamoto University
-
Uchida Ichiro
Department Of Anesthesiology Graduate School Of Medicine Osaka University
-
IOKIBE Tadashi
Research Institute of Application Technologies for Chaos & Complex Systems Co, Ltd.
-
KURIHARA Minako
Research Institute of Application Technologies for Chaos & Complex Systems Co, Ltd.
-
MANIWA Yoshio
Oya Research Institute of Advanced Health Science
-
OHTA Shoichi
Tokyo Medical University Kasumigaura Hospital Department of Acute Medicine
-
AMATA Mitsuyuki
Department of Anesthesiology, Osaka University Medical School
-
YAMAMOTO Motoki
2nd Department of Surgery, Wakayama Medical University
-
MANIWA Yoshio
Futaba clinic
-
Uchida I
Department Of Anesthesiology Osaka University Medical School
-
Iokibe T
Res. Inst. Application Technol. Chaos & Complex Systems Co. Ltd. Yokohama Jpn
-
Koyama M
Research Institute Of Application Technologies For Chaos & Complex Systems Co Ltd.
-
Amata Mitsuyuki
Department Of Anesthesiology Osaka University Medical School
-
Yamamoto Motoki
2nd Department Of Surgery Wakayama Medical University
関連論文
- Validity of Retinal Oxygen Saturation Analysis : Hyperspectral Imaging in Visible Wavelength with Fundus Camera and Liquid Crystal Wavelength Tunable Filter
- EXPRESSION OF OCCLUDIN IN NEWT TESTIS(Developmental Biology,Abstracts of papers presented at the 75^ Annual Meeting of the Zoological Society of Japan)
- Strabismus Surgery Using the Intraoperative Adjustable Suture Method Under Anesthesia With Propofol
- Mapping of putative ether-anesthesia resistance gene using C57BL/6J and MSM/Ms mouse strains
- Chaos-based Quantitative Health Evaluation and Disease State Estimation by Acceleration Plethysmogram
- Focus on metabolic syndrome trends using SOM (特集 生体情報解析と複雑系科学)
- SEMI-PERMEABLE BARRIER IN NEWT TESTIS(Cell Biology and Morphology,Abstracts of papers presented at the 76^ Annual Meeting of the Zoological Society of Japan)
- The Application of Pulse Wave Chaos in Clinical Medicine (第17回ファジィシステムシンポジウム--科学技術と自然の調和を目指して)
- Use of Chaos and Self-Organizing Maps for Acceleration Plethysmogram Information