2411 スキャナーレンズ組込用シュリンクフィッタの寸法公差の緩和
スポンサーリンク
概要
- 論文の詳細を見る
Improvement of lens positioning accuracy and temperature compensation of scanner lens system were possible by using a shrink fitter. However, the shrink fitter had to the processed at high dimensional accuracy in order to get fixed interference, and it became the high cost. Moreover if the interferance was larger than the designed value, the press fit had to be done. It caused the deterioration of lens positioning accuracy. In order to solve these problems two new methods of integrating the scanning lenses were developed. Their effectiveness were clarified by numerical analysis and experiment.
- 一般社団法人日本機械学会の論文
- 2002-09-20
著者
関連論文
- シュリンクフィッタを用いた高精度光学系によるレーザ微細加工装置の開発
- 2918 シュリンクフィッタ使った大口径走査レンズによるレーザ加工装置の開発
- 2411 スキャナーレンズ組込用シュリンクフィッタの寸法公差の緩和