Dynamic Behavior of a Scroll Compressor : Dynamic Analysis
スポンサーリンク
概要
- 論文の詳細を見る
This study presents an analytical method to reveal the dynamic behavior of a scroll-type compressor of small capacity. The calculated results are summarized on the basis of the gast-orque fluctuation, the crankshaft rotary behavior, the constraint forces at each pair of machine elements, the unbalanced forces of inertia, the compressor vibrations, the mechanical losses and the mechanical efficiency. It is concluded from this study that the scroll compressors have revolutionarily well-balanced dynamic characteristics in their vibrations, but have poor mechanical efficiency compared with the commonly used one-rolling-piston-type rotary compressors.
- 1988-03-15
著者
-
ISHII Noriaki
Faculty of Engineering, Osaka Electro-Communication University
-
FUKUSHIMA Masafumi
Compressor Division, Matsushita Electric Industrial Co. Ltd., (PANASONIC)
-
SAWAI Kiyoshi
Air Conditioning Research Laboratory, Matsushita Electric Industrial Co. Ltd., (PANASONIC)
-
SANO Kiyoshi
Air Conditioning Research Laboratory, Matsushita Electric Industrial Co. Ltd., (PANASONIC)
-
IMAICHI Kensaku
Osaka Hoki Co. Ltd.,
-
Sano Kiyoshi
Air Conditioning Research Laboratory Matsushita Electric Industrial Co. Ltd. (panasonic)
-
Sawai Kiyoshi
Air Conditioning Research Laboratory Matsushita Electric Industrial Co. Ltd. (panasonic)
-
Ishii Noriaki
Faculty Of Engineering Osaka Electro-communica-tion University
-
Fukushima Masafumi
Compressor Division Matsushita Electric Industrial Co. Ltd. (panasonic)
-
Imaichi Kensaku
Osaka Hoki Co. Ltd.
関連論文
- Dynamic Behavior of a Scroll Compressor : Dynamic Analysis
- Effects of Weir Plate Inclination Angle on Flow-Induced Vibrations of Long-Span, Shell-Type Gates
- Flow-Induced Vibration of Long-Span Gates due to Shed Vortices : Vibration Criteria, Level of Fluid Excitation and Added Mass
- Shbar Layer Behavior Under a Streamwise Vibrating Gate and Its Significance to Gate Vibration
- Dynamic Stability Criterion for Reed Valves in Refrigerant Compressors
- A Study on the Rotating Stall in Vaneless Diffusers of Centrifugal Fans (1st Report, Rotational Speeds of Stall Cells, Critical Inlet Flow Angle) : Fluids Engineering
- Instability of an Idealized Tainter-Gate System without Damping Caused by Surface Waves on the Back Water of Dam
- Water Waves and Structural Loads Caused by a Periodic Change of Discharge from a Sluice-Gate
- Flow-Induced Vibration of Long-Span Gates : Verification of Added Mass and Fluid Damping