C101 触媒式可燃性ガス再結合装置性能評価モデルの開発
スポンサーリンク
概要
- 論文の詳細を見る
The passive autocatalytic recombiner for flammable gas control in the light water reactor containment during postulated accident, has the unique feature which does not require any external driving force. However, the system performance has close interaction with thermal-hydraulic condition inside containment, and empirical correlations have been applied to date. Authors have developed mechanistic model which is applicable to extended atmospheric condition such as inerted containment. The new model has been incorporated into 3-dimensional CFD code, and verified against existing performance test data ranges from small to large scale. The analytical result shows good agreement with test data, and supports the model capability of recombiner performance prediction.
- 一般社団法人日本機械学会の論文
- 2000-10-30
著者
関連論文
- 2440 水平 U 字管を用いた原子炉の静的格納容器冷却系に関する研究
- S0803-3-4 コアキャッチャ冷却チャンネルにおける自然循環流動特性(原子力発電システムおよび要素技術(3))
- 1912 静的格納容器冷却系 (PCCS) 用横型熱交換器の性能評価伝熱モデルの開発
- C101 触媒式可燃性ガス再結合装置性能評価モデルの開発