大形油圧システムにおける折線形弁操作法
スポンサーリンク
概要
- 論文の詳細を見る
Oil column separation in the return line of a large oil hydraulic system is studied analytically, and the relation between the valve operation of the break-line mode and the rejoinder surge pressure is investigated. The valve operation of the break-line mode, which has a lower operating speed near the closing point, shortens the valve closing time without increasing the rejoinder surge pressure following the oil column separation. There is a region of the dimensionless valve opening corresponding to the break point of the valve operation, in which the rejoinder surge pressure is lowered. The critical value of this region depends upon the dimensionless parameters which describe the return line. The result obtained in this study is available for the design of the breakline mode valve operation which shortens the valve closing time.
- 一般社団法人日本機械学会の論文
- 1985-11-25
著者
関連論文
- 切換弁の折線形操作による油柱分離の再結合圧力について
- 自由鍛造プレスのもどり管路における油柱分離に関する一考察
- 大形油圧システムにおける折線形弁操作法
- 大形油圧システムの非定常現象--油圧式自由鍛造プレスのもどり管路内の油流
- 油圧式大形鍛造プレスの高速化に伴う諸現象-2-方向切換弁のタンク側圧力サ-ジについて
- 油圧式大形鍛造プレスの高速化に伴う諸現象-1-シリンダの異常作動および管路の衝撃音について
- 油圧駆動 (自動化システム設計入門ハンドブック) -- (機械要素)