Hydraulic Instability in Boiling Water Reactors
スポンサーリンク
概要
- 論文の詳細を見る
The hydraulic instability is one of the impermissible evils in the operation of BWR. And there has been no effective way of preventing it, because its mechanism is not clarified yet. The authors made many experiments with an electrically heated natural circulation loop which has electric condenser type void meters. As a result, they conclude that the hydraulic instability is a kind of non-linear oscillation caused by the combination of the fluid kinetics in the heated section and the non-linearity of the friction loss of the two-phase flow. They also derive analytically a block diagram of the circulation loop, in which the kinetics of fluid are simulated with simple linear transfer functions except the term of friction loss. The solutions, calculated by an analog computer, coincide well with the experimental results.
- 一般社団法人日本機械学会の論文
著者
-
Kurosu Kenji
Kyushu Institute Of Technology
-
Terano Toshiro
Tokyo Institute Of Technology
-
MURAYAMA Yujiro
Ship Research Institute
-
KUROSU Kenji
Transportation Technical Research Institute.
-
MURAYAMA Yujiro
Transportation Technical Research Institute.
-
OKUMURA Yukiteru
Transportation Technical Research Institute.
-
Terano T.
Tokyo Institute of Technology
関連論文
- 17. Condition Monitoring of Marine Engines by Means of Face Pattern Method
- 4. Study Boiler Efficiency Control
- Hydraulic Instability in Boiling Water Reactors