Dry State in a Contact Area of a Boiling Bubble on a Heating Surface
スポンサーリンク
概要
- 論文の詳細を見る
A dry part in a contact area of a boiling bubble on a wetted heating surface was observed by experiment using an electro-conductive glass. And size of the dry part was measured in the experiment, and it was compared with calculation based on vaporization by heat transfer through a thin liquid layer in the contact area of the bubble. And it was found that area of the dry part was roughly proportional to superheat of the heating surface and contact time of the bubble. And ratio of area of the part to total contact area in the heating surface was about 10% for any heat flux except very high and verly low heat flux at an atmospheric pressure in water of suturation.
- 一般社団法人日本機械学会の論文
著者
-
Torikai Kinichi
Heat Transfer Laboratory Japan Atomic Energy Research Institute
-
YAMAZAKI Toshi
Japan Atomic Energy Research Institute
関連論文
- Variation by Time in Boiling Heat Transfer Caused by Generation of Bubbles
- Heat Transfer in a Contact Area of a Boiling Bubble on a Heating Surface
- Dry State in a Contact Area of a Boiling Bubble on a Heating Surface
- Coefficient of Heat Transfer in Pool Boiling
- The Contact Area of Boiling Bubbles on the Heating Surface