Radial Force on the Impeller of a Centrifugal Pump
スポンサーリンク
概要
- 論文の詳細を見る
Radial force of a centrifugal pump was measured, using a pump which had a device for measuring the radial force and a volute casing with an interchangeable tongue. The authors obtained some knowledge about the following items and discussed them: (1) The effect of the cross-sectional area and shape of volute tongue on the pump characteristic and radial force. (2) The characteristic of dynamic component of radial force. (3) The effect of cavitation on the radial force.
- 一般社団法人日本機械学会の論文
著者
-
Shirai Toshiaki
Research Fellow Toyota Motor Co. Ltd.
-
UCHIDA Norio
Research and Development Center, Toshiba Corporation
-
Uchida Norio
Research Fellow Toshiba Research And Development Center. Tokyo Shibaura Electric Co. Ltd.
-
Imaichi Kensaku
Faculty Of Engineering Science Osaka University.
-
Imaichi Kensaku
Faculty Of Engineering Science Osaka University
関連論文
- 0.05 μm (3σ) Overlay Accuracy Through-the-lens Alignment in an Excimer Laser Lithography System
- Instability of an Idealized Tainter-Gate System without Damping Caused by Surface Waves on the Back Water of Dam
- Radial Force on the Impeller of a Centrifugal Pump
- Water Waves and Structural Loads Caused by a Periodic Change of Discharge from a Sluice-Gate
- AN ANALYSIS OF THREE-DIMENSIONAL UNSTEADY SUBSONIC FLOW THROUGH RECTILINEAR CASCADES
- AN ANALYSIS OF UNSTEADY TORQUE ON A QUASI-THREE-DIMENSIONAL CENTRIFUGAL IMPELLER