Measurements of the Isobaric Specific Heat Capacity of Gaseous Carbon Dioxide from 245K to 345K up to 3.7MPa
スポンサーリンク
概要
- 論文の詳細を見る
In order to reveal the calorimetric behavior of gases, an apparatus for the absolute determination of the isobaric specific heat capacity (Cp) of gases was carefully designed and constructed based on the flow calorimetry. Experimental results of Cp for gaseous carbon dioxide were obtained for temperatures from 245 K to 345 K and pressures up to 3.7 MPa including those near the saturation line. The overall experimental error of the Cp measurements was estimated to be less than 0.52%, and the reproducibility of these results was also confirmed to be less than 0.1%. The reported results were in good agreement with the available literature data within their experimental errors.
- 一般社団法人日本機械学会の論文
著者
-
KOBAYASHI Takashi
Faculty of Science and Engineering, Doshisha University
-
WATANABE Koichi
Faculty of Science and Technology, Keio University
-
Takaishi Yoshinori
Faculty Of Engineering Keio University
-
SAEGUSA Shogo
Faculty of Engineering, Keio University
-
Saegusa Shogo
Faculty Of Engineering Keio University
-
Watanabe Koichi
Faculty Of Engineering Keio University
-
Kobayashi Takashi
Faculty Of Engineering Keio University
-
Watanabe Koichi
Faculty of Agriculture, Tokyo University of Agriculture and Technology
関連論文
- Compact Multimode Horn with Coaxial Corrugation for Circular Coverage
- Increase in Phosphorus Availability of Upland Andosol under Different Fertilization Conditions Measured by Isotopic Techniques
- Measurements of the PVTx Properties of Binary Refrigerant R12+R22 System : First Report : A Mixture of 80 wt% R12+20 wt% R22
- Determination of the PVT-surface of Water based on the Measured Values up to 1123 K and 1 GPa
- Evaluation of Thermodynamic Properties of Fluids by Statistical Error Analysis : Compilation of Selected Values for the Specific Volume of Compressed Water
- Measurements of the Isobaric Specific Heat Capacity of Gaseous Carbon Dioxide from 245K to 345K up to 3.7MPa
- A Self-Confirming Engine for Preventing Man-in-the-Middle Attack(Security)(Internet Technology IV)
- On the Characteristics of a Bolted Joint with Tap Bolts : the case where a clamped part is a T-flange
- New Equation of State for Ordinary Water Substance in the Critical Region
- Considerations on the Improvement of the Stiffness of Bolted Joints in Machine Tools
- A Study on the Bending Rigidity of an Adhesive Joint Subjected to a Bending Load Tangential to Bonding Surfaces
- Correlation of Dew- and Bubble-Point Curves for Binary Refrigerant Mixtures
- On the Characteristics of a Bolted Joint with Tap Bolts : the case where a clamped part is a cover of a pressure vessel
- On the Characteristics of a Bolted Joint with Tap Bolts : the case where a clamped part is a circular flange
- The Strength of Combination Joints of an Adhesive with Bolts (T-Flange Adherends Subjected to an External Bending Moment)
- Effects of Magnetic Field on Metabolic Action in the Peripheral Tissue