Three Dimensional Flow Analysis in Boiler Furnaces
スポンサーリンク
概要
- 論文の詳細を見る
This paper presents a numerical method for the three dimensional analysis of gas flow in boiler furnaces. This method is based on the Modified FLIC Method, which is a kind of finite volume method, and on the anisotropic porous media modeling tube bundles. Two application examples are shown in this paper. The first example is of an experimental model boiler furnace, and the calculated results show a good agreement with experimental data. The other example is of an actual boiler furnace. In the latter example, three dimensional gas flow characteristics in furnace and the rectifying effect of panelled tubes at furnace outlet on a flow pattern are discussed.
- 一般社団法人日本機械学会の論文
著者
-
Adachi Takeshi
Mhi Nagasaki Tech. Inst.
-
SHIDA Hiroya
MHI Nagasaki Tech. Inst.
-
KURAGASAKI Mutsuo
MHI Nagasaki Tech. Inst.
-
KUNIMOTO Takeshi
MHI Power System Headquarters
-
HISATOME Masatoshi
MHI Power System Headquarters
関連論文
- Three Dimensional Flow Analysis in Boiler Furnaces
- On the Numerical Analysis Method of Flow and Heat Transfer in Condensers