Energy Losses Due to Division and Combination of Flow at 90° Wyes
スポンサーリンク
概要
- 論文の詳細を見る
The loss coefficients and the power-loss coefficients for a smooth symmetrical 90° wye with diameter ratio of unity were determined experimentally for each of all configurations of flow through the wye. Empirical equations for loss coefficients and those for power-loss coefficients were presented for each configuration of flow. The experiments were also carried out for a screwed symmetrical 90° wye which was manufactured according to the specification of the Japanese Industrial Standards. It was shown that the loss coefficients and the power-Ioss coefficients are markedly different from those for the smooth symmetrical 90° wye, and that they arc much affected by the axial length of the internal threads exposed to the flowing fluid. The loss coefficients for dead end wyes, in which the dead end was formed by closing the valve in the downstream, were also given.
- 一般社団法人日本機械学会の論文
著者
-
Sato Mitsumasa
Department Of Mechanical Engineering College Of Engineering Nihon University
-
Oka Kenji
Department Of Oral And Maxillofacial Prosthodontics And Oral Implantology The University Of Tokushim
-
ITO Hidesato
Institute of High Speed Mechanics, Tohoku University
-
Oka Kenji
Department Of Mechanical Engineering College Of Engineering Nihon University
-
Oka Kenji
Department Of Chemistry Faculty Of Science Ehime University
-
Ito Hidesato
Institute Of High Speed Mechanics Tohoku University
関連論文
- Estimation of Residual Stress in Dental Porcelain by Laser-Raman Spectroscopy
- Energy Losses Due to Division and Combination of Flow at 90° Wyes
- Influence of a Vent Hole on the Retentive Force of a Cement-retained Superstructure before/after Thermocycling
- A Novel Trimerization of 1-Phenylsulfanyl-2,2,2-trifluoroethyl Isocyanide Giving a Dihydropyrimidine Derivative
- Carbon dioxide laser application enhances the effect of silane primer on the shear bond strength between porcelain and composite resin