車両用たわみ板継手の疲労寿命評価
スポンサーリンク
概要
- 論文の詳細を見る
Flexible coupling plates to transmit the rotating power between traction motor and pinion are often subjected to surface damages such as fretting and / or pitting corrosion which may very rarely lead to fatigue failure. To evaluate the well-founded service life, specimens sampled from the coupling plates used during different service periods have been tested by a Schenck-type fatigue tester. The residual lives dominated by surface defects ; fretting and / or pitting corrosion, have been estimated in the lower stress amplitude range than the fatigue limit which occurs in actual loading, using modified Miner's rule. The permitted running distances after surface defects attain morphologically to a stable stage are evaluated to be 5 × 10^6 km for fretting and 3 × 10^6 km for pitting corrosion, in comparison with 12 × 10^6 km in case of no defect initiated, on the assumption that the upper half range in the maximum stress spectrum in service loading is effective to fatigue damage.
- 社団法人日本材料学会の論文
- 1996-10-15
著者
関連論文
- 高周波焼入れ鋼の転がり疲れき裂に及ぼす研削加工の影響
- オーステンパ球状黒鉛鋳鉄の転がり疲れに及ぼすショットピーニングの効果
- オーステンパ球状黒鉛鋳鉄の転がり疲れに及ぼすショットピーニングの効果 (特集・表面損傷の研究の最前線)
- オーステンパ球状黒鉛鋳鉄の水脆化特性
- 高強度鋳鉄の水濡れ状態での機械的性質
- 大気暴露試験による締付け軸力の異なる高強度ボルトの吸蔵水素量分布の評価
- 本四架橋で暴露されたボルト内の水素濃度分布
- 517 車両用たわみ板継手への Ti-4.5Al-3V-2Mo-2Fe 合金の適用
- 車両集電に関するトライボロジー : 種々のすり板材料の集電摩耗特性の比較
- 車両用たわみ板継手の疲労寿命評価
- 導電性セラミックスの摺動集電摩耗
- トロリー線とパンタグラフすり板
- 大電流の通過とトライボロジー:トロリ線とパンタグラフすり板
- 高強度鋼の遅れ破壊