A simple and harmless method is described for detecting the patency of ventriculo-peritoneal shunts with a pair of small disk thermistors. This method is based on the principle that when a moving column of fluid is locally cooled, a drop in temperature can be recorded at some distance from the place of application in the direction of the movement. A disk thermistor, measuring 6 mm in diameter covered with Epon 812 is taped to the chest skin just above the shunt tube 4 cm distal from the cooling point, and the other thermistor, the reference one, is also taped to the skin beside the shunt tube 4 cm distal from the cooling point. They are balanced so that, when the measuring thermistor detects a drop in temperature, a pen-deflection occurs. As a cold source we use an ordinary cube of ice in a vinyl sack for one minute. In the experiment a shunt tube was embedded in clay, the results of which showed a significant pen-deflection between different flow velocities, ranging from 5 ml/h to 60 ml/h (120 ml/24 hrs and 1,440 ml/24 hrs). In clinical data there were 23 hydrocephalic children and 9 adult patients with normal pressure hydrocephalus, and they were examined 26 and 10 times respectively. Three out of 23 hydrocephalic children could not be examined because of their violent movements, but all of the adult patients could be examined. In all 25 patients whose clinical pictures suggested functioning shunts, the proper diagnosis of shunt patency was obtained by this methods. In 6 patients whose clinical pictures were dubious as to whether the shunt was patent or not, this method revealed that all shunts were patent and their CT scans and follow-up data supported shunt patency. In 2 patients whose clinical pictures suggested shunt malfunction, this method revealed no pen-deflection, and their shunt obstructions were proved by operations. This method is a simple and safe procedure which may be repeated at frequent intervals.
- 社団法人 日本脳神経外科学会の論文
- 1980-03-15
著者
関連論文
- 原発性cerebral neuroblastomaの1例
- 二分脊椎における脊髄係瘤症候群の術後管理
- 超音波骨メスを利用した棘突起縦割式頚部脊柱管拡大術 : 超音波骨メスの有用性について
- 小さなthermistorを用いた新しい髄液短絡管機能判定法
- CTスキャンにおける髄膜腫に伴う抵吸収域 : 脳血管写との比較
- 小児頭部外傷について--教室〔横浜市大脳神経外科〕における最近三年間の入院症例の検討
- 脳浮腫 (抗炎症剤の再検討--適応症から副作用の対策まで) -- (副腎皮質ステロイド剤の使い方)
- 水頭症shunt手術の希有なる合併症 : 髄液の脳実質内進展
- 新しい流量過多防止装置の流量特性 : Integra Referential Valve と Dual-Switch Valve の基礎実験による比較
- シャントの流量過多,流量不足の防止
- 水頭症治療における短路管(短路術)の工夫
- 第34回 日本平衡神経科学会
- 頸静脈孔神経鞘腫の診断と治療
- Intraluminal Arterial Pressure Measurement for Carotid Stenosis