Model equations of fluorescent lamps on the high frequency operation(2)
スポンサーリンク
概要
- 論文の詳細を見る
Model equations of fluorescent lamps were investigated as well on the high frequency operation. In the analysis of operating of the fluorescent lamp, the model equation of equivalent conductance of lamp on the high frequency is needed to performed. The model equations are estimated by the error-rate between the experimental waveform and the simulation waveform on the various operating frequecies. Any comparisons of differential model equations, model constants, and other components are discussed by relating characteristics of the fluorescent lamps on the high frequency operation. By using the delay time for the lamp voltage and lamp current, the error-rate values are improved. In each category of model equations, the most significant model equations are discussed. Some of the model equations are most suitable to simulate the characteristics of fluorescent lamp, therefore the ability of the model equations on the high frequency operation are increased.
- 社団法人照明学会の論文
著者
-
NAKAMURA Kimihiko
Department of Gynecology and Obstetrics, Faculty of Medicine
-
BO Hiroshi
Department of Electronic Engineering, Faculty of Engineering, Kobe University
-
Nakamura Kimihiko
Department Of Electronic Faculty Of Engineering Kobe University
-
TOLA Muhammad
Division of Material Science, The Graduate School of Science and Technology, Kobe University
-
Bo Hiroshi
Department Of Electrical Engineering Kobe University
-
Bo Hiroshi
Department Of Electronic Faculty Of Engineering Kobe University
-
Tola M
Division Of Material Science The Graduate School Of Science And Technology Kobe University
-
Tola Muhammad
Division Of Material Science The Graduate School Science And Technology Kobe University
関連論文
- Bestatin, an Aminopeptidase Inhibitor, Promotes Follicular Growth and Ovulation Suppressed by Stress in Mice
- Simple and Low Cost Multichannel Spectral Measurement System for Weak Light
- Photoluminescence in CdTe Films Deposited by Evaporation in H_2
- Model equations of fluorescent lamps on the high frequency operation(2)
- Time Dependence and Excitation-Intensity Dependence of Luminescence in CdTe
- The Decay Time Constants of Photo-Induced ESR of Cr^+ in ZnS
- The Decay Behavior of Photo-Induced Electron Spin Resonance of Chromium in Zinc Sulfide
- Application of the lamp model equation to HID lamps with various voltage
- An investigation of the model constants for the fluorescent lamps with resistance ballast circuit
- Deterioration After Surgical Treatment of Spinal Dural Arteriovenous Fistula Associated With Spinal Perimedullary Fistula : Case Report