Color Appearance in Peripheral Vision : Effects of Test Stimuli and Surround Luminance
スポンサーリンク
概要
- 論文の詳細を見る
To determine the appropriate experimental conditions for measuring the color zone map covering the visual field, the color appearances of red, yellow, green, and blue lights of a CRT display presented across the horizontal meridian of the visual field were measured. The test stimulus settings were equal luminance and equal brightness at the fovea, with dark, gray, or white surround conditions. The perceived strength of the red, yellow, green, and blue hue components in the test stimuli decreased from the fovea to the periphery under all conditions. The luminance level of the test stimuli and the surround conditions did not significantly affect the results. All four of the unique-hue component curves as a function of the eccentricity normalized at the fovea were within the range of the data obtained in previous studies in which monochromatic lights were used as the test stimuli. These curves may thus not depend on whether the test stimulus is monochromatic or complex light. The recommended experimental conditions for measuring the color zone map are equal- luminance test stimuli (no need for brightness-matching testing) with a gray surround (more applicable to actual visual environments than a dark or white surround).
- 社団法人照明学会の論文
著者
-
Hayashi Hirofumi
Department of Cardiology, Surugadai Nihon University Hospital
-
Sakurai Masato
Department Of Cardiology Nabari City Hospital
-
Sakurai Masato
Department Of Production And Information Science Graduate School Of Engineering Utsunomiya Universit
-
Ayama Miyoshi
Department Of Information Science Faculty Of Engineering Utsunomiya University
-
Ayama Miyoshi
Department Of Information And Control Systems Science Graduate School Of Engineering Utsunomiya Univ
-
KOSEKI Takayuki
Department of Information Science, Faculty of Engineering, Utsunomiya University
-
Koseki Takayuki
Department Of Information Science Faculty Of Engineering Utsunomiya University
-
Hayashi Hirofumi
Department Of Information Science Faculty Of Engineering Utsunomiya University
-
Hayashi Hirofumi
Department Of Applied Chemistry And Biotechnology Faculty Of Engineering Yamanashi University
-
Hayashi Hirofumi
Departmemt of Cardiology, Surugadai Nihon University Hospital
関連論文
- THE EFFECTS OF CENTRAL AND SYSTEMIC 6-HYDROXYDOPAMINE (6-OHDA) PRETREATMENT ON HEMODYNAMIC RESPONSE WITH CENTRAL ADMINISTRATION OF 5-HYDROXYTRYPTAMINE (5-HT) IN RATS : Hypertension(II) : II : 48 Annual Scientific Meeting, Japanese Circulation Society
- Simultaneous Determination of _L-Phenylalanine and Branched-chain _L-Amino Acids in Plasma by Liquid Chromatographic System with a Coimmobilized Enzyme Reactor and Fluorescence Detection
- Transition Process from Laminar to Oscillatory Marangoni Convection in a Liquid Bridge under Normal and Micro Gravity
- The Relationship between Aortic Pulse Wave Velocity and Augmentation Index : An Invasive Study(Hypertension, Clinical 9 (H), The 69th Annual Scientific Meeting of the Japanese Circulation Society)
- Reflected Pressure Wave is a Major Determinant of Increased Aortic Pulse Pressure with Advancing Age(Hypertension, Clinical 1 (H), The 69th Annual Scientific Meeting of the Japanese Circulation Society)
- Effect of Gravity on Marangoni Convection in a Liquid Bridge
- π^+P Elastic Scattering and Impact Parameter
- MARANGONI CONVECTION IN A LIQUID BRIDGE UNDER MICROGRAVITY CONDITIONS DURING PARABOLIC FLIGHT
- INTERFACIAL CONTAMINATION CAUSED BY WATER ON MARANGONI CONVECTION IN A SILICONE OIL LIQUID BRIDGE
- Experimental Results of Oscillatory Marangoni Convection in a Liquid Bridge under Normal Gravity
- PJ-612 Effects of aging on arterial compliance in human subjects. : An invasive study(Hypertension, Basic and Clinical (H) : PJ103)(Poster Session (Japanese))
- PJ-118 Decreased arterial compliance and increased heart rate are major determinants of reduced arterial baroreflex sensitivity in the clinical setting(Hypertension, Clinical 2 (H) : PJ20)(Poster Session (Japanese))
- What Are Determinants of Stroke Volume-to-Aortic Pulse Pressure Ratio?
- The Stroke Volume-to-Aortic Pulse Pressure Ratio Is a Reliable Estimate of Total Arterial Compliance in Human Subjects
- Effects of Contrast and Character Size upon Legibility of Japanese Text Stimuli Presented on Visual Display Terminal
- BMO and PPST Approaches to Meson States in Broken SU_4 Symmetry
- Electromagnetic Structure of the Nucleon and Vector Mesons
- Color Appearance in Peripheral Vision : Effects of Test Stimuli and Surround Luminance
- Machinery of Inclusive J Particle Production at PS-Energy pN Collision
- The effect of intravenous 6-hydroxydopamine pretreatment on hemodynamic response with intracerebroventricularly administered 5-hydroxytryptamine in conscious rats
- The effect of ritanserin on intracecerebroventricular 5-hydroxytryptamine induced hemodynamic and plasma norepinephrine responses in conscious rats