マイクロガスタービンを用いたコージェネレーションシステムの住宅地への導入効果
スポンサーリンク
概要
- 論文の詳細を見る
For energy conservation and CO2 reduction, cogeneration systems may be useful. This paper shows the effectiveness of the cogeneration system, used in a residential area and designed to supply heat by hot water pipelines. The cogeneration system consists of a micro gas turbine (MGT) generator and a boiler. Entire heat load is supplied by the MGT or boiler, while an electric load may be supplied by an electric power company. Optimal diameter of the hot water pipeline becomes large when the load density becomes low. Total heat supply loss is less then 10% for moderate temperature region. However, it exceeds 20% for a sparse load in the cold region. The MGT should generates heat just required by the load for the primary energy or cost minimum operation. In the moderate temperature region, primary energy reduction ratio is positive in almost all cases, while it becomes negative in the cold region. On the other hand, CO2 emission almost always decreases in some extent. In the warm or moderate temperature region, MGT cogeneration systems are effective for energy conservation. They are also effective for CO2 reduction in almost all cases.
- 2010-12-01
著者