Effect of PLC Signal Induced into VDSL System by Conductive Coupling
スポンサーリンク
概要
- 論文の詳細を見る
We investigated the effect of a high-speed power line communication (PLC) signal induced into a very high-speed digital subscriber line (VDSL) system by conductive coupling based on a network model. Four electronic devices with AC mains and telecommunication ports were modeled using a 4-port network, and the parameters of the network were obtained from measuring impedance and transmission loss. We evaluated the decoupling factor from the mains port to the telecommunication port of a VDSL modem using these parameters for the four electric and electronic devices. The results indicate that the mean value of the decoupling factor for the differential and common mode signals were more than 88 and 62dB, respectively, in the frequency range of a PLC system. Taking the following parameters into consideration; decoupling factor Ld, the average transmission signal powers of VDSL and PLC, desired and undesired (DU) ratio, and transmission loss of a typical 300-m-long indoor telecommunication line, the VDSL system cannot be disturbed by the PLC signal induced into the VDSL modem from the AC mains port in normal installation.
- (社)電子情報通信学会の論文
- 2010-07-01
著者
-
YAMANE Hiroshi
NTT Facilities Inc.
-
KUWABARA Nobuo
Kyusyu Institute of Technology
-
Akiyama Yoshiharu
Ntt Corp. Musashino‐shi Jpn
-
Akiyama Yoshiharu
Ntt Energy And Environment Systems Lab. Tokyo Jpn
-
Kuwabara Nobuo
Department Of Electrical Engineering Kyushu Institute Of Technology
-
Kuwabara Nobuo
Dept. Of Electrical Engineering And Electronics Kyushu Institute Of Technology
-
Kuwabara Nobuo
Kyushu Institude Of Technology
-
AKIYAMA Yoshiharu
NTT East Corporation
関連論文
- Effect of PLC Signal Induced into VDSL System by Conductive Coupling
- Calculation of longitudinal conversion loss and input impedance for indoor AC mains line considering high-speed PLC
- Calculation of Electromagnetic Field Emitted from UTP Cable by Moment Method from 0.3GHz to 2GHz
- Macroscopic visualization of a radiated emission source using cylindrically scanned electric field amplitude data
- Comparison of site attenuation analysis results between FDTD and ray-tracing method using compact anechoic chamber
- Investigation of Radiated Emission Characteristics of Balanced Cable by Using Analysis Method that Takes a Balance-Unbalance Conversion Factor into Consideration
- Effect of PLC Signal Induced into VDSL System by Conductive Coupling
- Method of Evaluating Shielding Effect of Enclosure Using Disc-Cone Antenna Operated by O/E Converter from 1GHz to 8GHz
- Effect of Discharge Gap Shape on High-Speed Electrostatic Discharge Events