Surface treatments of titanium anodized in phosphoric acid solution and in vitro cell responses (特集 傾斜機能・生体材料)
スポンサーリンク
概要
- 論文の詳細を見る
TiO2 layer was fabricated on commercially pure titanium using an anodic spark oxidation technique with 1M phosphoric acid solution. Subsequent heat or water treatment was performed to improve the biocompatibility of oxide layers. Surface characteristics of oxide layers before and after subsequent treatments and their influence on the cell response were investigated. It was found that the oxide layer without subsequent treatments exhibited a porous surface structure with few nanometer features. Thin film X-ray diffraction analysis and electron probe microanalysis indicated that the oxide layer consisted of amorphous or poorly crystallized oxides with the incorporation of phosphorus. After heat treatment (500°C, 3 h), the crystallinity degree of oxide layer increased, but only slight change in the surface morphology was observed. In contrast, water treatment (80°C, 48 h) not only can significantly transform the amorphous oxides into crystalline anatase, but also result in a nanostructured surface. In vitro biocompatibility study of oxide layers demonstrated better cell response to water treated oxide layer than untreated one.
- 2010-05-15
著者
-
CHEN Zhao-Xiang
Research Institute for Applied Mechanics, Kyushu University
-
WANG Wen-Xue
Research Institute for Applied Mechanics, Kyushu University
-
TAKAO Yoshihiro
Research Institute for Applied Mechanics, Kyushu University
-
MATSUBARA Terutake
Research Institute for Applied Mechanics, Kyushu University
-
REN Li-Mei
Research Institute for Applied Mechanics, Kyushu University
-
Chen Zhao-xiang
Research Institute For Applied Mechanics Kyushu University
-
Ren Li-mei
Research Institute For Applied Mechanics Kyushu University
-
Wang Wen-xue
Research Institute For Applied Mechanics Kyushu University
-
Matsubara Terutake
Research Institute For Applied Mechanics Kyushu University
-
Takao Yoshihiro
Research Inst. For Applied Mechanics Kyushu Univ.
関連論文
- Surface treatments of titanium anodized in phosphoric acid solution and in vitro cell responses (特集 傾斜機能・生体材料)
- Evaluation of the biomechanical characteristic of tooth supporting structure under occlusal load (特集 傾斜機能・生体材料)
- The Alternation of Peri-Implant Bone Response Exposed to Static Lateral Load
- An Analysis of the T-Shaped Crack Along the Fiber-Matrix Interface in Unidirectional Composite Materials
- Interaction Between Cracks Perpendicular to and on the Interface in Composite Materials
- Modeling of time-dependent behavior of deformation and transverse cracking in cross-ply laminates
- Three-Dimensional Damage Analysis of a Pin-Loaded CFRP Quasi-Isotropic Laminate under Various Temperatures
- Reliability of Structural Components under Non-Periodic Inspection and the Optimum Inspection Plan
- Mechanical Behaviours of Single-Edge-Crack Rectangular Tensile Plates with Uniform Vertical End Displacement
- OS9(4)-14(OS09W0096) Effect of Loading and Thermal History on Electric Resistance in CFRP
- Evaluation by FEM of temperature-dependent damage behavior in quasi-isotropic carbon/epoxy laminates
- Changes in Surface Characteristics of Anodized Titanium Arising from Water Immersion (特集 傾斜機能・生体材料)
- Changes in Surface Characteristics of Anodized Titanium Arising from Water Immersion
- Evaluation of Deformation Distribution in Alveolar Bone Model around Dental Implant with Numerical Approach