The Analysis of the Load Exerted on the Implants Supporting an Overdenture Based on In Vivo Measurement
スポンサーリンク
概要
- 論文の詳細を見る
The aims of this study were to measure the three-dimensional (3-D) loads exerted on the implants supporting an overdenture during function in vivo and to clarify the effect of the number of the implants on the loads. The load-measuring devices were mounted on the implants inserted in the mandible of a 62 aged female subject. Either two or four implants connected with a bar were used for supporting her overdenture. The loads on the implants were expressed three dimensionally as load vectors and were analyzed in the coordinates based on the Frankfort horizontal plane and sagittal plane. The tasks examined were maximum voluntary clenching (MVC) and gum chewing (GC). The total load exerted on the implants with a four-implant supported overdenture (4I-Od) was larger than that with a two-implants supported overdenture (2I-Od) at MVC. The maximum occlusal force on the overdenture showed the same manner (p<0.01). The directions of the loads were posterior and lateral at MVC. The total load exerted on the implants located on the working side, was larger than that on the implants located on the non-working side during GC in the case of 4I-Od. The similar manner was also observed in the 2I-Od. The tensile loads were registered during GC. The functional loads exerted on the individual implants in the case of 4I-Od were smaller than those in the 2I-Od. The loads on the implants during function are thus affected by the number of implants supporting the overdenture.
- 日本補綴歯科学会の論文
- 2008-07-01
著者
-
SASAKI Keiichi
Division of Advanced Prosthetic Dentistry, Tohoku University Graduate School of Dentistry
-
KURIYAGAWA Tsunemoto
Department of Mechatronics and Precision Engineering, Tohoku University
-
Sasaki Keiichi
Division Of Advanced Prosthetic Dentistry Tohoku University Graduate School Of Dentistry
-
YODA Nobuhiro
Division of Advanced Prosthetic Dentistry, Tohoku University Graduate School of Dentistry
-
OGAWA Toru
Division of Advanced Prosthetic Dentistry, Tohoku University Graduate School of Dentistry
-
GUNJI Yoshinori
Division of Advanced Prosthetic Dentistry, Tohoku University Graduate School of Dentistry
-
KAWATA Tetsuo
Division of Advanced Prosthetic Dentistry, Tohoku University Graduate School of Dentistry
-
Yoda Nobuhiro
Division Of Advanced Prosthetic Dentistry Tohoku University Graduate School Of Dentistry
-
Kawata Tetsuo
Division Of Advanced Prosthetic Dentistry Tohoku University Graduate School Of Dentistry
-
Gunji Yoshinori
Division Of Advanced Prosthetic Dentistry Tohoku University Graduate School Of Dentistry
-
Kuriyagawa Tsunemoto
Department Of Mechatronics And Precision Engineering Tohoku University
-
Kuriyagawa Tsunemoto
Department Of Nanomechanics Tohoku University Graduate School Of Engineering
-
Ogawa Toru
Division Of Advanced Prosthetic Dentistry Tohoku University Graduate School Of Dentistry
-
Sasaki Keiichi
Division Of Advanced Prosthetic Dentistry Graduate School Of Dentistry Tohoku University
関連論文
- Calcium Phosphate Formation on Ti-Ag Alloys in Simulated Body Fluid
- Ultra-Precision Arc Truing and Dressing of Diamond Wheels for Aspheric Mirror Grinding
- Ulitaprecision Machining Characteristics of Poly-Crystalline Germanium
- Ultraprecision Machining Characteristics of Poly-crystalline Germanium(Ultra-precision machining)
- Tissue-biomaterial Interface Research for Prosthodontic Dentistry
- The Analysis of the Load Exerted on the Implants Supporting an Overdenture Based on In Vivo Measurement
- Powder Jet Deposition of Ceramic Films(M^4 processes and micro-manufacturing for science)
- Analysis of physicochemical properties of octacalcium phosphate prepared by hydrolysis and co-precipitation with fluoride ions
- C22 Study on Nonisothermal Glass Molding Press for Aspherical Lens(Ultra-precision machining)
- Development of Micro Ultrasonic Abrasive Machining System : 1st Report, Studies in Micro Ultrasonic Abrasive Machining
- Development of in vivo measuring system of the pressure distribution under the denture base of removable partial denture
- C24 Cutting Performance of a Single-crystalline Diamond Ball Endmill in Fabricating Micro Lens Arrays and Grooves(Ultra-precision machining)
- C21 Wear Mechanism of Diamond Tools in Ductile Machining of Reaction-bonded Silicon Carbide(Ultra-precision machining)
- 110 Study of Parallel Grinding Method for Aspheric Optical Elements
- Development of an AFM-Based System for In-Process Measurement of Micro-Defects on Machined Surfaces
- Modeling high-temperature glass molding process by coupling heat transfer and viscous deformation analysis
- Development of an electrorheological fluid-assisted polishing tool for micro-aspherical molding dies(M^4 processes and micro-manufacturing for science)
- Fundamental investigation of subsurface damage in single crystalline silicon caused by diamond machining
- Nondestructive measurement of machining-induced amorphous layers in single-crystal silicon by laser micro-Raman spectroscopy
- The dynamic viscoelasticity and water absorption characteristics of soft acrylic resin materials containing adipates and a maleate plasticizer
- Tactile sensation and occlusal loading condition of mandibular premolars and molars
- Interleukin-6 Maintains Glucose Homeostasis to Support Strenuous Masseter Muscle Activity in Mice
- Biomechanical Evaluation of Amorphous Calcium Phosphate Coated TNTZ Implants Prepared Using a Radiofrequency Magnetron Sputtering System
- Resistance Formed in Thermoplastic Resin Substrate by Laser-Assisted Micro Powder Jet Implantation
- Corrosive effect of disinfection solution containing hydroxyl radicals generated by photolysis of H_2O_2 on dental metals
- Laminated Capacitor Formed in Thermoplastic Resin Substrate by Laser-Assisted Micropowder Jet Implantation
- Influence of a new denture cleaning technique based on photolysis of H2O2 the mechanical properties and color change of acrylic denture base resin
- The influence of polymerization conditions on color stability of three indirect composite materials
- A high-sensitive and non-radioisotopic fluorescence dye method for evaluating bacterial adhesion to denture materials
- Statistical Approach Optimizing Slant Feed Grinding
- Time course of bone metabolism at the residual ridge beneath dentures observed using ^F-fluoride positron emission computerized-tomography/computed tomography (PET/CT)
- A high-sensitive and non-radioisotopic fluorescence dye method for evaluating bacterial adhesion to denture materials
- A retrospective study of fixed dental prostheses without regular maintenance
- Bone metabolism of residual ridge beneath the denture base of an RPD observed using NaF-PET/CT