Experimental Investigation of Steam Condensation Phenomena Using a Multihole Sparger with a Bottom Hole
スポンサーリンク
概要
- 論文の詳細を見る
KAERI has performed a series of steam condensation tests to assess the performance of a unit cell sparger that will be used in the APR1400 reactor. A simplified I-sparger with a bottom hole was used for the steady-state steam condensation tests to study the characteristics of the condensation phenomena in a multihole sparger. Ranges of steam mass fluxes and pool temperatures for the condensation tests were selected to study the effect of a bottom hole on the overall steam condensation phenomena in a unit cell tank. General trends of the condensation loads and the variations in the frequencies of the pressure waves due to steam condensation in a multihole sparger with a bottom hole are presented. The test data is compared with that of previous condensation tests that used a sparger without a bottom hole and the results show that a sparger with a bottom hole significantly reduces the magnitude of the condensation loads.
- 一般社団法人 日本原子力学会の論文
- 2008-09-01
著者
-
Song Chul
Korea Atomic Energy Research Institute
-
Park Choon
Korea Atomic Energy Research Institute
-
Youn Young
Korea Atomic Energy Research Institute
-
JUN Hyung
Korea Atomic Energy Research Institute
関連論文
- Experimental Investigation of Steam Condensation Phenomena Using a Multihole Sparger with a Bottom Hole
- Experimental Investigation of the Steam Condensation Phenomena due to a Multi-hole Sparger