Fabrication of DEP Device for Cell Positioning and its Cell Viability Test
スポンサーリンク
概要
- 論文の詳細を見る
Studies pertaining cell chips require a cell positioning technique for the application of cell engineering such as single cell analysis, etc. Dielectrophoresis (DEP) is one of the promising methods to realize simultaneous multi-cell positioning. Previously, several research groups performed DEP-based cell manipulation, for example, cell separation, sorting, and positioning. In this study, we verify cell viability after positioning by DEP. We have fabricated a saw-shaped electrode on a glass chip and demonstrated simultaneous multi-cell positioning wherein cells are arranged between electrodes using the negative DEP principle. We describe the designs of two types of electrodes as well as their electric field simulations. The test chips were fabricated by the standard microelectromechanical system (MEMS) technology, and the experiments were performed for both polystyrene beads and living cells. To investigate the influence of DEP on the cell, the viability of the cells after the positioning was examined using a fluorescent dye. The results of this examination confirmed that no cytotoxicity was observed in the case of negative DEP positioning. Consequently, it was shown that the principle of negative DEP can be applied to achieve cell positioning without having a hazardous effect on living cells.
- 社団法人 電気学会の論文
- 2008-02-01
著者
-
Tanaka Yasuhiro
Department Of Digestive And Life-style Related Diseases Kagoshima University Graduate School Of Medi
-
Tanaka Yasuhiro
Department Of Cardiovascular Medicine Tokyo Medical And Dental University
-
Yanagida Yasuko
Precision&inteligence Laboratory Tokyo Institute Of Technology
-
Yanagida Yasuko
Precision And Intelligence Laboratory Tokyo Institute Of Technology
-
HATSUZAWA Takeshi
Precision and Intelligence Laboratory, Tokyo Institute of Technology
-
Hatsuzawa Takeshi
Precision And Intelligence Laboratory Tokyo Institute Of Technology
-
Tanaka Yasuhiro
Department Of Advance Materials Science Faculty Of Engineering Kagawa University
-
Tanaka Yasuhiro
Department Of Mechano-micro Engineering Interdisciplinary Graduate School Of Science And Engineering
関連論文
- Novel ECG Predictor of Difficult Cases of Outflow Tract Ventricular Tachycardia : Peak Deflection Index on an Inferior Lead
- OE-223 Radiofrequency Catheter Ablation (RFA) for Patients with Premature Ventricular Contractions (PVC) can Improve Sympathetic Nerve Activity of I-123 MIBG Imaging(OE38,Nuclear Cardiology (Others) (I),Oral Presentation (English),The 73rd Annual Scientif
- End-systolic and end-diastolic left atrial volume assessment by two-dimensional echocardiography : a comparison study with magnetic resonance imaging
- PJ-611 Multi-Slice Computed Tomography Reveals the Non-uniform Wall Thickness of the Left Atrial Antrum in patients with Atrial Fibrillation(PJ103,CT/MRI (Myocardium) 2 (I),Poster Session (Japanese),The 73rd Annual Scientific Meeting of The Japanese Circu
- PJ-236 The Prompt Systolic Blood Pressure Rise Just after the Initiation of Cardiac Resynchronization Therapy Predicts the Long-term Clinical Outcome(PJ040,CRT/ICD 2 (M),Poster Session (Japanese),The 73rd Annual Scientific Meeting of The Japanese Circulat
- PJ-156 Efficacy of Confirmation of Complete Conduction Block of Left Atrium Roof Linear Ablation for Atrial Fibrillation(PJ026,Atrial/Supraventricular Arrhythmia (Clinical/Treatment) 1 (A),Poster Session (Japanese),The 73rd Annual Scientific Meeting of Th
- PJ-018 Long-Term Clinical Efficacy and Risk of Catheter Ablation for Atrial Fibrillation in the Elderly(PJ003,Atrial/Supraventricular Arrhythmia (Clinical/Diagnosis) (A),Poster Session (Japanese),The 73rd Annual Scientific Meeting of The Japanese Circulat
- PJ-016 Reduction of Cardiovascular Events Associated with Atrial Fibrillation by Hybrid Therapy in Patients with Hypertrophic Cardiomyopathy(PJ003,Atrial/Supraventricular Arrhythmia (Clinical/Diagnosis) (A),Poster Session (Japanese),The 73rd Annual Scient
- PE-485 New Strategies of Anticoagulation Management in the Periprocedual Period for Atrial Fibrillation Ablation(PE081,Arrhythmia, Others (Clinical/Diagnosis/Treatment) 4 (A),Poster Session (English),The 73rd Annual Scientific Meeting of the Japanese Circ
- PE-072 What Kind of Patients is Susceptible to the Detrimental Effects of Chronic Pacing from the Right Ventricular Apex?(PE012,Heart Failure (Treatment) 1 (M),Poster Session (English),The 73rd Annual Scientific Meeting of The Japanese Circulation Society