In this paper, we report on experimental results dealing with the minimum ignition energy (MIE) of coating polymer powders. An important result was found that some of the samples examined were so sensitive that even a spark with a very low energy, such as 2 mJ, could ignite them. The values of the discharge spark energy of ignition testing set by the BSI (British Standards Institution) standards and the FM (Factory Mutual) regulations related to the safe operation of electrostatic powder coating systems are sufficiently high to result in the ignition of some of the coating powders. Therefore, it is imperative that more appropriate discharge spark energy values in testing be defined for safety assessment in electrostatic powder coating systems.
- Japan Society of Applied Physicsの論文
- 2005-04-10
著者
-
SHIN Dae
Department of Mechanical Engineering, Pohang University of Science and Technology
-
Shin Dae
Department Of Mechanical Engineering Pohang University Of Science And Technology
-
Shin Dae
Department Of Safety Engineering Seoul National University Of Technology
-
YAMAGUMA Mizuki
Independent Administrative Institution, National Institute of Industrial Safety
-
Joung Jae
Department Of Safety Engineering Seoul National University Of Technology
-
Yamaguma Mizuki
Independent Administrative Institution Japan National Institute Of Occupational Safety And Health
-
Yamaguma Mizuki
Independent Administrative Institution National Institute Of Industrial Safety
-
Choi Kwang
Independent Administrative Institution Japan National Institute Of Occupational Safety And Health
-
Choi Kwang
Independent Administrative Institution National Institute Of Industrial Safety
-
Shin Dae
Department Of Internal Medicine School Of Medicine Cha University
関連論文
- Velocity Field Measurements of Flow inside Snout of Continuous Hot-Dip Galvanizing Process Using a Single-frame PIV Technique
- Experimental Study on Electrostatic Spark Ignitability of Coating Polymer Powders in Electric Field with Corona Discharge
- Electric Spark Ignition Eneries of Coating Polymer Powders
- Ignitability of sprayed liquids due to an electrostatic spark
- A case of successful management of HHV-8^+, EBV^+ germinotropic lymphoproliferative disorder (GLD)
- Experimental Study on Safe Performance of Nozzle-Type Electrostatic Neutralizer
- Experimental Study on Electrostatic Spark Ignitability of Coating Polymer Powders in Electric Field with Corona Discharge