Detection of Hepatocellular Carcinoma Using Double-echo FLASH Sequence during the Hepatic Arterial Phase
スポンサーリンク
概要
- 論文の詳細を見る
Purpose: The purpose of this study was to compare the performance of in-phase and opposed-phase gradient-recalled echo (GRE) pulse sequences in paramagnetic contrast-enhanced magnetic resonance (MR) imaging of hepatocellular carcinomas (HCCs) during the hepatic arterial phase. Material and methods: Thirty-four patients with 84 lesions with known or suspected HCCs, nine of whom had a fatty liver, were examined with double-echo GRE techniques under 1.5T before and 30 s after injection of gadopentenate dimeglumine at a dose of 0.1 mmol/kg. Echo times were 2.4 ms (opposed phase) and 5.0 ms (in phase). Contrast enhancement of the HCC detected in both in-phase and opposed-phase images was evaluated. The liver signal-to-noise ratio (SNR), lesion-liver contrast-to-noise ratio (CNR), and enhancement ratio (ER) were calculated for the largest lesion of each patient. Results: In dynamic gadolinium-enhanced images of the 84 HCCs, 81 (96.4%) were detected in both in-phase and opposed-phase images, two (2.4%) were detected in only in-phase images, and one (1.2%) was detected only in opposed-phase images. The liver SNR, CNR, and ER were 46.7±16.1, 15.2±10.3, and 0.637±0.268 for in-phase images, and 48.9±16.9, 16.3±11.8, and 0.647±0.309 for opposed-phase images, respectively. In patients with a fatty liver, the SNR, CNR, and ER were 46.0±18.1, 21.7±17.9, and 0.525±0.231 for in-phase images, and 44.3±18.7, 26.0±21.3, and 0.793±0.124 for opposed-phase images, respectively. No significant statistical differences were found between the in-phase and opposed-phase images. Conclusion: Opposed-phase GRE imaging is equivalent to in-phase GRE sequences in patients with or without fatty liver for detection of HCC in dynamic gadolinium-enhanced images.
- 日本磁気共鳴医学会の論文
- 2004-07-15
著者
-
Yamashita Yasuyuki
Department Of Radiology Kumamoto University
-
Yamashita Yasuyuki
熊本大学 医学薬学研究部放射線診断学
-
Yanaga Yumi
熊本大学 医学薬学研究部放射線診断学
-
Awai Kazuo
熊本大学 医学薬学研究部放射線診断学
-
Awai Kazuo
Department Of Radiology Kumamoto University
-
山下 康行
熊本大学 放射線医
-
Yamaguchi Yasuo
Department Of Surgery Ii Kumamoto University Medical School
-
NAKAYAMA Yoshiharu
Department of Diagnostic Radiology, Graduate School of Medical Sciences, Kumamoto University
-
山下 康行
熊本大 医 放射線医学
-
ARAKAWA Akihiko
Departments of Radiology, and Maxillofacial Surgery, Kumamoto University School of Medicine
-
NAMIMOTO Tomohiro
Department of Radiology, Minamata City Hospital
-
MORISHITA Shoji
Department of Diagnostic Radiology, Kumamoto University Postgraduate School
-
ARAKI Yuhshi
Department of Radiology, Minamata City Hospital
-
Yamashita Yasuyuki
Department Of Diagnostic Imaging Faculty Of Medical And Pharmaceutical Sciences Kumamoto University
-
Araki Yuhshi
Department Of Radiology Minamata City Hospital
-
Awai Kazuo
Department Of Diagnostic Radiology Graduate School Of Medical Sciences Kumamoto University
-
Arakawa Akihiko
Department Of Diagnostic Radiology Kumamoto University Postgraduate School
-
Morishita Shoji
Department Of Diagnostic Radiology Kumamoto University Postgraduate School
-
Yamashita Yasuyuki
Department Of Diagnostic Radiology Kumamoto University Postgraduate School
-
Awai Kazuo
Department Of Analysis Of Diagnostic Imaging Kumamoto University Postgraduate School
-
Nakayama Yoshiharu
Department Of Diagnostic Radiology Kumamoto University Postgraduate School
-
Namimoto Tomohiro
Department Of Diagnostic Radiology Graduate School Of Medical Sciences Kumamoto University
-
Namimoto Tomohiro
Department Of Radiology Minamata City Hospital
-
Nakayama Yoshiharu
Department Of Diagnostic Radiology Graduate School Of Medical Sciences Kumamoto University
関連論文
- 吻合部仮性動脈瘤に対するステントグラフト内挿術の経験
- X線CT装置のAutomatic Exposure Control (AEC) 使用時の線量と画像ノイズの検討 : スキャノグラムと寝台位置の影響
- P-060. 左利き被験者の area Gの位置-利き手と area Gの位置の関係(ポスターセッション, 2006年度日本味と匂学会第40回大会)
- P2-21 fMRIによるヒト大脳皮質第一次味覚野の同定(2005年度日本味と匂学会第39回大会)
- SF-030-2 安全なラジオ波凝固療法を目指した,低分化型肝細胞癌の術前予測(肝治療-1,サージカルフォーラム,第110回日本外科学会定期学術集会)
- Contrast Enhancement for Whole-body Screening Using Multidetector Row Helical CT : Comparison between Uniphasic and Biphasic Injection Protocols
- 脳腫瘍の3T MRI (特集 3T MRIの現状と展望)
- 短径8チャンネルコイルによる新生児頭部MRI
- DTI in the Head and Neck Region with Parallel Imaging Technique at 3T MR
- 脳梗塞の血管撮影と画像解析の意義 (インターベンション時代の脳卒中学(改訂第2版)(下)超急性期から再発予防まで) -- (脳梗塞)
- 3次元MRA画像を用いた脳動脈瘤検出アルゴリズムの開発(画像工学 3次元画像処理, 一般研究発表予稿集, 日本放射線技術学会第33回秋季学術大会)
- MRIにおける下垂体脳腫瘤の鑑別診断のための人工ニューラルネットワークの最適化(画像工学 画像認識・画像抽出等, 一般研究発表予稿集, 日本放射線技術学会第33回秋季学術大会)
- ANNを用いたMRIにおける下垂体腫瘤の鑑別診断(画像工学 画像認識・画像抽出等, 一般研究発表予稿集, 日本放射線技術学会第33回秋季学術大会)
- 呼吸停止下造影エコー併用経皮的エタノール注入療法が残存腫瘍に対して有効であった原発性肝細胞癌の1例
- 非切除膵癌に対する動注療法に起因した仮性肝動脈瘤を伴う肝膿瘍の1例
- 膵癌の術前肝転移診断 : 経上腸間膜動脈性門脈造影下CT(CTAP)+肝動脈造影下CT(CTHA)の有用性
- PJ-052 Quantitative Assessment of Total Coronary Artery Plaques Volume Using Multi-slice Computed Tomography is Associated with Metabolic Syndrome(PJ009,CT/MRI (Coronary/Vascular) 4 (I),Poster Session (Japanese),The 73rd Annual Scientific Meeting of The J
- 胃憩室の検討
- 高分解能ヘリカルCTを用いた膵臓疾患の診断 (特集 螺旋CT実践的活用のポイント)
- MR検査中に熱傷を生じた2症例
- 臨床講義 食道癌の放射線治療
- PJ-052 Quantitative Assessment of Total Coronary Artery Plaques Volume Using Multi-slice Computed Tomography is Associated with Metabolic Syndrome(PJ009,CT/MRI (Coronary/Vascular) 4 (I),Poster Session (Japanese),The 73rd Annual Scientific Meeting of The J
- 声門癌症例に対する根治的放射線治療後の生命予後 : 新TNM分類(UICC第6版)での検討
- DP-004-2 ラジオ波凝固療法の安全性と治療成績向上のための工夫 : 画像診断と腫瘍マーカーによる低分化型肝細胞癌の予測(第107回日本外科学会定期学術集会)
- Role of cardiac computed tomography in patients with suspected coronary artery disease : interaction with nuclear cardiology
- Initial experience with X-ray CT based attenuation correction in myocardial perfusion SPECT imaging using a combined SPECT/CT system
- Attenuation correction using combination of a parallel hole collimator and an uncollimated non-uniform line array source
- Attenuation correction using asymmetric fanbeam transmission CT on two-head SPECT system
- CT Portography by Multidetector Helical CT : Comparison of Three Rendering Models
- マルチスライスCT at RSNA2000 (特集 RSNA2000)
- 3.マルチディテクターヘリカルCTの肺ガン検診への応用(第40回 日本肺癌学会九州支部会)
- ガドリニウム造影三次元 MR angiography
- Multi-row detector CTの活用 (特集 コントラスト・メディアの新潮流--マルチスライスCTの実践的活用)
- Visualization of the Heterogeneous Internal Structure of So-called "Pancreatic Necrosis" by Magnetic Resonance Imaging in Acute Necrotizing Pancreatitis
- Percutaneous Embolization of the Distal Pancreatic Duct to Treat Intractable Pancreatic Juice Fistula
- Relationship Between Plasma Cytokine Concentration and Multiple Organ Failure in Patients with Acute Pancreatitis
- 肺結節のthin slice helical CTデータの定量解析による良悪性の推定(シンポジウム: 『ROC解析の統計, 解析ソフト, 応用』, 第57回画像分科会)
- Identification and characterization of focal ground-glass opacity in the lungs by high-resolution CT using thin-section multidetector helical CT : experimental study using a chest CT phantom
- Prediction of aortic peak enhancement in monophasic contrast injection protocols at multidetector CT : phantom and patient studies
- Digital Cine Angiography Permits Radiation Dose Reduction without Reduction in Image Quality
- Differential diagnosis of nodular lesions in cirrhotic liver by post-vascular phase contrast-enhanced US with Levovist : comparison with superparamagnetic iron oxide magnetic resonance images
- OJ-200 Increased Pericardial Fat Volume is Associated with Presence of Coronary Artery Plaques with or without Coronary Stenosis and Positive Remodeling(OJ34,Atherosclerosis (Clinical/Pathophysiology) (IHD),Oral Presentation (Japanese),The 73rd Annual Sci
- The diagnostic efficacy of FDG-PET in the local recurrence of hilar bile duct cancer
- Solitary necrotic nodule of the liver
- Clinical Role of Non-Contrast Magnetic Resonance Angiography for Evaluation of Renal Artery Stenosis
- Management of sentinel lymph nodes in malignant skin tumors using dynamic lymphoscintigraphy and the single-photon-emission computed tomography/computed tomography combined system
- Optimum energy window setting on Hg-201 x-rays photopeak for effective Tl-201 imaging
- Accurate scatter correction for transmission computed tomography using an uncollimated line array source
- Hyperoxia-induced Acute Lung Injury Using a Pig Model: Correlation between MR Imaging and Histologic Results
- Effects of Propentofylline on Tumor Necrosis Factor-α and Cytokine-Induced Neutrophil Chemoattractant Production in Rats with Cerulein-Induced Pancreatitis and Endotoxemia
- Radiation dose reduction in hepatic multidetector computed tomography with a novel adaptive noise reduction filter
- Dynamic MR Imaging and Radiotherapy
- 頭頸部腫瘍に合併する食道癌
- MR血管撮影
- 18.Screlosing hemangiomaの1例 : 第38回日本肺癌学会九州支部会
- Reduction of Radiation Dose at HRCT of the Temporal Bone in Children
- 読影支援の手段である遠隔画像診断による地域医療推進 (総特集 不況下での画像診断機器戦略)
- Ectopic cervical thymus in an infant
- Optimal dose and injection duration (injection rate) of contrast material for depiction of hypervascular hepatocellular carcinomas by multidetector CT
- Multidetector CT findings suggesting a perforation site in the gastrointestinal tract : analysis in surgically confirmed 155 patients
- Differential Diagnosis of Small Round Cervical Lymph Nodes: Comparison of Power Doppler US with Contrast-enhanced CT and Pathologic Results
- Detection of Hepatocellular Carcinoma Using Double-echo FLASH Sequence during the Hepatic Arterial Phase
- Role f Preoperative Helical CT before Laparoscopic Cholecystectomy : Evaluation of Gallbladder and Peritoneal Adhesion
- Evaluation of Hypervascular Hepatocellular Carcinoma in Cirrhotic Liver by Means of Helical CT : Comparison of Different Contrast Medium Concentrations within the Same Patient
- MR Imaging of the Anterior Cruciate Ligament: Value of Thin Slice Direct Oblique Coronal Technique
- Percutaneous Microwave Coagulation Therapy: An Experimental Study
- Metastatic Liver Tumor from Cystic Ovarian Carcinomas:CT and MRI Appearance
- The Value of Fast and Ultrafast T2-weighted MR Imaging Sequences in Hepatic Enhancement with Ferumoxides:Comparison with Conventional Spin-echo Sequence
- Calculation of T2 Relaxation Time from Ultrafast Single Shot Sequences for Differentiation of Liver Tumors:Comparison of Echo-planar, HASTE, and Spin-echo Sequences
- MRIは壊死性膵炎における, いわゆる膵壊死巣内の不均一な内部構造を描出する
- Quantitative Evaluation of Measurement Accuracy for Three-dimensional Angiography System Using Various Phantoms
- Intraarterial Infusion Chemotherapy for Head and Neck Cancers : Evaluation of Tumor Perfusion with Intraarterial CT during Carotid Arteriography
- Usefulness of Source Images from Three-dimensional Time-of-flight MR Angiography after Treatment of Cavernous Dural Arteriovenous Fistulas
- Endometrial adenocarcinoma following the conservative treatment of an atypical polypoid adenomyoma
- Intracranial Artery Dissections : Serial Evaluation with MR Imaging, MR Angiography, and Source Images of MR Angiography
- The detection rates and tumor clinical/pathological stages of whole-body FDG-PET cancer screening
- Synchronous spontaneous arteriovenous fistula and aneurysm of the deep femoral artery incidentally found in a patient with aortic aneurysmal dissection
- 子宮肉腫の画像診断 (特集 婦人科がん画像診断の最先端)
- Remort desktop を利用したリアルタイム遠隔放射線治療計画・支援システムの構築
- 肺小結節の線量計算アルゴリズムにおける散乱補正の重要性 : 臨床症例での検討
- PREPARATION AND EVALUATION OF W/O TYPE AND W/O/W TYPE EMULSIONS CONTAINING AN ANTICANCER DRUG
- 5-Fluorouracil Intra-arterial Infusion Combined With Systemic Gemcitabine for Unresectable Pancreatic Cancer
- Preoperative Detection of Liver Metastases Secondary to Pancreatic Cancer : Utility of Combined Helical Computed Tomography During Arterial Portography With Biphasic Computed Tomography-Assisted Hepatic Arteriography
- T2声門癌に対するUFTおよび低濃度CDDP同時併用化学放射線療法の初期経験 : MRIによる治療前評価
- 肺小結節照射における散乱線量補正アルゴリズムの重要性 : ファントムモデルでの検証
- 食道癌に対するT字照射における画一的線量分布補正 : 重複照射野法 (field within a field technique) の応用
- 肝内結石症の画像診断 (特集 肝内結石症)
- ガドリニウム造影3次元躯幹部MR angiography
- Transjugular Intrahepatic Portosystemic Shunt: Initial Clinical Experience and Three-Year Follow-up
- Functional Evaluation of Transplanted Kidneys by Gd-DTPA Enhanced Turbo FLASH MR Imaging
- MR Imaging of Hepatocellular Carcinoma Arising in Genetic Hemochromatosis
- Detection of liver metastases secondary to pancreatic cancer: Utility of combined helical computed tomography during arterial portography with biphasic computed tomography-assisted hepatic arteriography
- Estimation of 123I-IMP arterial blood activity from dynamic planar imaging of the chest using a graph plot method for the quantification of regional cerebral blood flow
- Clinical usefulness of a collimator distance dependent resolution recovery in myocardial perfusion SPECT : a clinical report from a single institute
- Does adding FDG-PET to MRI improve the differentiation between primary cerebral lymphoma and glioblastoma? Observer performance study
- Liver functional volumetry for portal vein embolization using a newly developed ^Tc-galactosyl human serum albumin scintigraphy SPECT-computed tomography fusion system
- Type 1 Perimedullary Arteriovenous Fistula with Subarachnoid Hemorrhage : Utility of Contrast-enhanced 3D Gradient-echo Technique
- Multi-tensor Tractography of the Motor Pathway at 3T : A Volunteer Study
- ^C MR Imaging of Methionine-rich Gliomas at 4.7T : A Pilot Study
- Improvement of the ^Tc-ECD brain uptake ratio (BUR) method for measurement of cerebral blood flow